75
19. KM-2200SWJ3
Specification Sheet
AC SUPPLY VOLTAGE
208-230/60/3
AMPERAGE
12.8 A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
30 A
MAXIMUM FUSE SIZE
30 A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
2850 (3.11)
2830 (3.06)
WATER gal./24HR (gal./100 lbs.)
330 (15.0)
469 (21.1)
WATER COOLED CONDENSER
2090 (95)
1222 (55)
gal./24HR (gal./100 lbs.)
ICE PRODUCTION PER CYCLE
42.7 lbs. (19.4 kg) 2160pcs.
BIN CONTROL SYSTEM
Mechanical
REFRIGERANT CHARGE
R404A, 2 lb. 16 oz. (1360g)
Performance Data Sheet
70/21
2221
1007
2215
1005
2089
947
80/27
2216
1005
2207
1001
2015
914
90/32
2215
1005
2200
998
2033
922
lbs./day kg./day
100/38
2150
975
2161
980
1880
853
70/21
80/27
90/32
watts
100/38
70/21
1690
6.40
1904
7.21
2356
8.92
80/27
1853
7.01
2185
8.27
2725
10.32
90/32
1904
7.21
2420
9.16
2932
11.10
gal./day m
3
/day
100/38
2294
8.68
2540
9.61
3403
12.88
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
258
18.1
259
18.2
265
18.6
80/27
259
18.2
261
18.4
268
18.9
90/32
259
18.2
263
18.5
269
18.9
PSIG kg/cm
2
G
100/38
262
18.4
264
18.6
275
19.3
70/21
50
3.5
50
3.5
50
3.5
80/27
50
3.5
50
3.5
50
3.5
90/32
50
3.5
50
3.5
50
3.5
PSIG kg/cm
2
G
100/38
50
3.5
50
3.5
50
3.5
27,200 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,800 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
WATER FLOW FOR CONDENSER
129 gal./h [AT 100ºF (38ºC) / WT 90ºF (32ºC)]
PRESSURE DROP OF COOLING WATER LINE
less than 10 PSIG
3.2
2.8
2.8
HEAD PRESSURE
SUCTION PRESSURE
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
3.9
3.6
3.5
3.7
3.2
3.3
3.6
2.8
2.8
30
26
25
29
27
26
32
2803
2832
2700
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
26
26
28
26
25
APPROXIMATE ELECTRIC
CONSUMPTION
2830
2836
2779
2834
2844
2751
2836
2850
2772
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
ENG.F-011.1.0205