37
an inoperative Comp, or an inoperative HM. If the unit switches out of freeze with F/S
connector removed, but would previously not switch out of freeze with F/S connected
(long freeze - 3 beep alarm), F/S may be sticking. To check and clean F/S, see "IV.D.
Float Switch Check and Cleaning." If the unit remains in freeze longer than 15 seconds
after disconnecting black F/S connector, replace CB.
Note: Normal freeze cycle will last 20 to 40 minutes depending on model and
conditions. Cycle times and pressures should follow performance data provided in
this manual. See "III.C. Performance Data."
6)
Pump-Out Cycle
– (10/20 second pump-out) – LEDs 1, 3, and 2 are on.
LED 4
is on when S4 dip switch 3 & 4 are set to 3 off and 4 on.
CAUTION! Do not adjust
S4 dip switch 3 & 4 to 3 off and 4 on. Adjustment to this position on this model
prevents the pump motor from rotating in the pump-out direction.
For details, see
"II.C.2.c) Pump-Out Timer (S4 dip switch 3 & 4)." Comp and FMR remain energized,
HGV energizes. WV energizes if S4 dip switch 3 off and 4 on. LLV and FM de-energize.
PM stops for 2 seconds, then reverses for 10/20 seconds depending on pump-out
timer S4 dip switch 3 & 4 setting. When the pump-out timer terminates, the pump-
out is complete. The pump-out frequency control is factory set for every 10th cycle,
and generally no adjustment is required. However, where water quality is bad and the
icemaker needs a pump-out more often, the pump-out frequency can be adjusted.
The pump-out frequency control (S4 dip switch 5 & 6) can be set to have a pump-out
occur every cycle, or every 2, 5, or 10 cycles.
Timing of the first pump-out is dependent
on S4 dip switch 5 & 6 settings. See the table below.
S4 Dip Switch Setting
Pump-Out
Frequency
1st Pump-Out
No. 5
No. 6
OFF
OFF
Every cycle
After 2nd freeze cycle
ON
OFF
Every 2 cycles
After 3rd freeze cycle
OFF
ON
Every 5 cycles
After 6th freeze cycle
ON
ON
Every 10 cycles
After 11th freeze cycle
Diagnosis:
If PM does not reverse, check to see if CB S4 and S5 dip switch settings
are in the factory default position. If S4 dip switch 3 and 4 are adjusted to 3 off and 4 on,
WV and harvest pump timer relays energize. Once these relays energize, the pump
motor rotates in the freeze cycle rotation. See "III.B. Wiring Diagrams." Check PM circuit
and capacitor, check #5 pin (DBu wire) on CB K1 ten-pin connector for voltage, harvest
pump timer X1 and X2 relays (auxiliary code T-0, U-0), X10 and X11 relays (auxiliary
code U-1 and later). If water does not pump out, check and clean the check valve
assembly and tubing.
7)
Normal Harvest Cycle
–
same as the initial harvest cycle – Return to "IV.A.4) Initial
Harvest Cycle."