g) Internal Booster Tank Thermistor Error (H3, H4)
Z(" F@6a J666a4K
JF=K
de-energize, "H3" appears in the display, and the buzzer sounds.
Z(" !%5aJ%F6a4KJP6<K
the thermistor leads are considered open and the internal booster tank heaters de-energize,
"H4" appears in the display, and the buzzer sounds.
Z*" "
Z !"
HW !
Note: See “III.E. Thermistor Check” and “IV.M. Removal and Replacement of Thermistor.”
Control Board
Defective.
Replace.
Thermistor
Connector not properly
connected.
Reconnect.
Open circuit (H4).
Replace.
Thermistor senses abnormal temperature.
H 3 / H 4
Code Error
Item Possible
Cause
Remedy
Continues (internal
booster tank heater off).
Operation
Short circuit (H3).
Replace.
Defective.
Replace.
Connector not properly
connected.
Reconnect.