26
c) Wash Tank Water Level Error (A3)
Z("! ! !! 3/*'
&*'[ *@ $$
sounds.
Z&"! "
Z !"
Overflow Pipe
Out of position.
Set in position.
Control Board
Defective.
Replace.
Connector not properly
connected.
Reconnect.
Wash Tank Water Level
Sensor (Wash Tank
Electrode)
Heavy scale or soil
buildup.
Clean.
Connector not properly
connected.
Reconnect.
Open circuit.
Repair or replace.
Defective.
Replace.
Wash tank water level sensor opens in
“
READY
”
mode or
“
STANDBY.
”
A 3
Code Error
Item Possible
Cause
Remedy
Auto fill cycle starts.