31
h) Compressor Run Time (F7)
To display the compressor run time between the two most recent defrosts, follow the
steps below.
1) Make sure the jumper is removed between the connector K151 pins 7 and 8 on the
control board. Otherwise you will not be able to access this feature.
2) Press and hold both the
button and the
unmarked, blank button for 5 seconds.
"F0" should appear in the display window. Press the MANUAL DEFROST button until
"F7" appears in the display window.
3) Press the
unmarked, blank button to display the run time. The number displayed
indicates what percent of the time the compressor was running.
4) Press the MANUAL DEFROST button to return to the menu screen. Press and hold
both the
button and the
unmarked, blank button for 5 seconds to exit the setting
mode and return to the temperature display.
5) If a jumper was present between connector K151 pins 7 and 8, reconnect it after all
setting and diagnostic work is complete.
4. Operating Modes
Hoshizaki undercounters and worktops feature two operating modes, energy saving and
continuous. Always use the default setting of your unit. To determine the default setting
of your unit, see the chart below.
Continuous
(no period after temperature)
Energy Saving
(period after temperature)
Model
Default Setting
Refrigerator (auxiliary code Q5 and earlier)
Continuous Operating Mode
Refrigerator (auxiliary code Q6 and later)
Energy Saving Operating Mode
Freezer - 1 section
Continuous Operating Mode
Freezer - 2 section
Energy Saving Operating Mode
To determine the operating mode your unit is in, look at the unit's cabinet temperature
display. If a period does not appear after the temperature, the unit is in continuous
operating mode. If a period appears after the temperature, the unit is in energy saving
operating mode.
To switch between operating modes, press and hold the
unmarked, blank button for
5 seconds.
Note: It takes 5 seconds for this setting to be saved. Once saved, the setting you made
will be remembered even if the power is turned off.
Summary of Contents for HUF40A
Page 6: ...6 Units mm in 1a HUR40A D HUF40A D 1 HUR40A HUF40A ...
Page 7: ...7 2 HWR40A HWF40A Units mm in 2a HWR40A D HWF40A D ...
Page 8: ...8 3 HUR68A HUF68A Units mm in 3a HUR68A D HUF68A D ...
Page 9: ...9 4 HWR68A HWF68A Units mm in 4a HWR68A D HWF68A D ...
Page 10: ...10 5 HUR96A 5a HUR96A D Units mm in ...