3) (While pressing the Option Button) Press the Stop Button once.
4) The Display indicates the error record.
5) Check that the error record indication becomes “- -“.
6) (While pressing the Option Button) Press the Stop Button once again.
7) The Display indicates the error record (ongoing error).
8) Release the Option Button. The Display changes back to the normal indication.
(ex.)
If there is no ongoing error, the Display indicates “- -“.
If the icemaker is in the errors “E0”, “c1” and “c2”, the Display repeatedly indicates “E0” (1
sec)
à
“c1” (1 sec)
à
“c2” (1 sec).
(4) Delete error record
The error record is not deleted by turning off the power supply but is deleted by the following
button operation. To make the next service diagnosis easier, it is recommended to delete
the error record during maintenance or service.
Button Operation: (Power supply ON, Operation Switch on “STOP”)
1) While pressing both the Option Button and Stop Button together, move the Operation
Switch to the “RUN” position.
2) When the Display illuminates “ICE”, release the Stop Button first and then the Option
Button.
(5) Indicate cycle time
The cycle time to estimate the current ice production capacity is indicated by the following
button operation.
This cycle time means the time since the Float Tank fills up during Compressor operation
until the next icemaking water supply starts. The last five cycles are recorded.
This record is deleted when the power supply is turned off.
Button Operation: (Power supply ON, Operation Switch on “RUN”)
1) Keep on pressing the Option Button until step 4).
2) The Display changes from the normal indication to the total operating hours.
3) (While pressing the Option Button) Press the Ice Button once.
4) The Display indicates the cycle time.
5) Release the Option Button. The Display changes back to the normal indication.
As the Display can indicate only two digits, a complex system is used to indicate the cycle
time record. The max five cycles are indicated from the latest to the oldest as “_ _” min “_ _”
sec …… “_ _” min “_ _” sec. The Display illuminates “ICE” after all the record has been
indicated.
E2AH5820209
17