background image

FM-150KE

FM-150KE-N

FM-150KE-50

FM-150KE-50-N

FM-120KE

FM-80KE

FM-80KE-N

L1F080111 (093014)

SELF-CONTAINED ICE MAKER

INSTRUCTION MANUAL 

Summary of Contents for FM-120KE

Page 1: ...FM 150KE FM 150KE N FM 150KE 50 FM 150KE 50 N FM 120KE FM 80KE FM 80KE N L1F080111 093014 SELF CONTAINED ICE MAKER INSTRUCTION MANUAL...

Page 2: ...ION 3 5 INSTALLATION 3 6 ELECTRICAL CONNECTIONS 3 7 WATER SUPPLY AND DRAIN CONNECTIONS 4 II OPERATING INSTRUCTIONS 5 1 START UP 5 2 SHUT DOWN 5 3 PREPARING THE ICEMAKER FOR LONG STORAGE 6 III MAINTENA...

Page 3: ...considered improper and therefore dangerous The manufacturer will not be held liable or responsible for any damage caused by improper incorrect and unreasonable use The installation and relocation if...

Page 4: ...icemaker it will not work properly 1 After removing the packaging make sure that the icemaker and the storage bin are in good condition If in doubt please do not use the icemaker but refer to profess...

Page 5: ...TION CAUTION Incorrect installation can cause harm to people animals or other items for which the manufacturer cannot be held responsible 1 Position the icemaker in the selected permanent site 2 Level...

Page 6: ...0 5 bar and maximum 0 8 MPa 8 bar If the pressure exceeds 0 8 MPa 8 bar use a proper pressure reducing valve Do NOT throttle back the supply tap The dual check valve must be connected in the icemaker...

Page 7: ...ice To keep the icemaker hygienic Wash your hands before removing ice Use the plastic scoop provided accessory The storage bin is for ice use only Do not store anything else in the bin nor use other...

Page 8: ...ter jet CAUTION When using a neutral cleaner or sodium hypochlorite thoroughly read and understand the instructions provided to prevent potential health problems NOTICE Ask a trained service person to...

Page 9: ...as required e Air Filter Plastic mesh air filters remove dirt or dust from the air and keep the condenser from getting clogged If the filters get clogged the icemaker s performance will be reduced Rem...

Page 10: ...motor failure Turn OFF operation switch and turn it ON again If error code appears again call for service EF Supply voltage is too low Check that voltage is in required range and icemaker is not shar...

Page 11: ...140kg ambient 10 C water 10 C 150kg ambient 10 C water 10 C Dimensions 640mm W x 600mm D x 800 798 833 mm H 640mm W x 600mm D x 800 798 833 mm H 940mm W x 600mm D x 800 798 833 mm H Refrigerant R134a...

Page 12: ...s fluorinated greenhouse gases covered by the Kyoto Protocol FM 150KE N R134a GWP 1430 0 22kg FM 120KE R134a GWP 1430 0 22kg CM 140KE R134a GWP 1430 0 22kg CM 110KE 50 R134a GWP 1430 0 22kg FM 150KE 5...

Reviews: