background image

7

ENGLISH

[c] Storage Bin Interior Cleaning/Sanitisation (Weekly)

1) Open the storage bin door, and remove all ice.

2) Slightly warp the slope to release it from the left and right shafts.

3) Remove the drain cap located in the base of the storage bin.

4) Wash the bin liner, slope and drain cap with a neutral non-abrasive cleaner. 

Rinse thoroughly.

Note: Take care not to damage the bin control actuator at the top of the bin.

5) Either mix 5 litres of water with 18 ml of 5.25% sodium hypochlorite solution in a 

suitable container, or the recommended Hoshizaki sanitiser as directed.

6) Soak a clean sponge or cloth with the solution, and wipe the bin liner surfaces, slope and drain cap.

7) Refit the slope and drain cap.

8) Wipe the surface of the bin door with the solution. Close the bin door.

9) The remaining solution can be used to sanitise utensils.

Note: Do not wipe dry or rinse after sanitising, but allow to air dry.

[d] Storage Bin Door

Clean the storage bin door at least once a week, using a neutral non-abrasive cleaner. Rinse thoroughly after cleaning and 

sanitise as required.

[e] Air Filter

Plastic mesh air filters remove dirt or dust from the air, and keep the condenser from getting clogged. If the filters get clogged, 

the icemaker’s performance will be reduced. Remove and clean the air filter(s) at least twice per month:

1) Slide the air filter off the louver.

2) Clean  the  air  filter  by  using  a  vacuum  cleaner.  When  severely  clogged,  use 

warm water and a neutral cleaner to wash the air filter.

3) Rinse and dry the air filter thoroughly.

NOTICE

After cleaning, be sure to place the air filter back in position.

2. INSPECTION AND MAINTENANCE

NOTICE

To achieve optimum icemaker performance, the following parts need periodic inspection and maintenance:

 

Extruding head (upper bearing)

 

Housing (lower bearing)

 

Mechanical seal

These parts should be inspected after two years from installation or 10,000 hours of operation, whichever comes first, and once 

a year afterwards. Replacement of these parts is required if wear exceeds factory recommendations.

Their service life, however, depends on water quality and environment. More frequent inspection and maintenance are 

recommended in bad or severe water conditions.

Consult with your local Hoshizaki service agent about inspection and maintenance service.

Air Filter

Louver

Drain Cap

Slope

Summary of Contents for FM-120KE

Page 1: ...FM 150KE FM 150KE N FM 150KE 50 FM 150KE 50 N FM 120KE FM 80KE FM 80KE N L1F080111 093014 SELF CONTAINED ICE MAKER INSTRUCTION MANUAL...

Page 2: ...ION 3 5 INSTALLATION 3 6 ELECTRICAL CONNECTIONS 3 7 WATER SUPPLY AND DRAIN CONNECTIONS 4 II OPERATING INSTRUCTIONS 5 1 START UP 5 2 SHUT DOWN 5 3 PREPARING THE ICEMAKER FOR LONG STORAGE 6 III MAINTENA...

Page 3: ...considered improper and therefore dangerous The manufacturer will not be held liable or responsible for any damage caused by improper incorrect and unreasonable use The installation and relocation if...

Page 4: ...icemaker it will not work properly 1 After removing the packaging make sure that the icemaker and the storage bin are in good condition If in doubt please do not use the icemaker but refer to profess...

Page 5: ...TION CAUTION Incorrect installation can cause harm to people animals or other items for which the manufacturer cannot be held responsible 1 Position the icemaker in the selected permanent site 2 Level...

Page 6: ...0 5 bar and maximum 0 8 MPa 8 bar If the pressure exceeds 0 8 MPa 8 bar use a proper pressure reducing valve Do NOT throttle back the supply tap The dual check valve must be connected in the icemaker...

Page 7: ...ice To keep the icemaker hygienic Wash your hands before removing ice Use the plastic scoop provided accessory The storage bin is for ice use only Do not store anything else in the bin nor use other...

Page 8: ...ter jet CAUTION When using a neutral cleaner or sodium hypochlorite thoroughly read and understand the instructions provided to prevent potential health problems NOTICE Ask a trained service person to...

Page 9: ...as required e Air Filter Plastic mesh air filters remove dirt or dust from the air and keep the condenser from getting clogged If the filters get clogged the icemaker s performance will be reduced Rem...

Page 10: ...motor failure Turn OFF operation switch and turn it ON again If error code appears again call for service EF Supply voltage is too low Check that voltage is in required range and icemaker is not shar...

Page 11: ...140kg ambient 10 C water 10 C 150kg ambient 10 C water 10 C Dimensions 640mm W x 600mm D x 800 798 833 mm H 640mm W x 600mm D x 800 798 833 mm H 940mm W x 600mm D x 800 798 833 mm H Refrigerant R134a...

Page 12: ...s fluorinated greenhouse gases covered by the Kyoto Protocol FM 150KE N R134a GWP 1430 0 22kg FM 120KE R134a GWP 1430 0 22kg CM 140KE R134a GWP 1430 0 22kg CM 110KE 50 R134a GWP 1430 0 22kg FM 150KE 5...