PROBLEM
POSSIBLE CAUSE
REMEDY
[2] Overflow from
reservoir (Water
does not stop.)
a) Water supply
1. Water pressure too
high.
1. Install a pressure reducing
valve.
b) Water valve
1. Diaphragm does not
close.
1. Clean or replace.
c) Float switch
1. Bad contacts.
1. Check for continuity and
replace.
[3] Gear motor
protector operates
frequently.
a) Power supply
voltage
1. Too high or too low.
1. Connect the unit to a power
supply of proper voltage.
b) Evaporator assy
1. Bearings or auger
worn out.
1. Replace bearing or auger.