![Hoshizaki FM-120KE-50-HC Service Manual Download Page 4](http://html1.mh-extra.com/html/hoshizaki/fm-120ke-50-hc/fm-120ke-50-hc_service-manual_2165200004.webp)
1
I. SPECIFICATIONS
1. DIMENSIONS/SPECIFICATIONS
[a] FM-120KE-HC
ITEM
HOSHIZAKI FLAKE ICE MAKER
FM-120KE-HC
1 Phase 220-240V 50Hz
Capacity: 0.60kV
A (2.5A)
2.0A
Starting: 8.8A
Flake
640mm(W) × 600mm(D) × 800(798
~
833)mm(H)
HFC Free
655W (Ambient
Temp. 32°C, W
ater
Temp. 21°C)
Stainless Steel, Galvanized Steel (Rear)
Thin ice forming inside Cylinder (Flake Ice)
Direct Connection to W
ater Main, Inlet: G3/4 (Rear)
Outlet: R3/4 (Rear)
Hermetic
Fin and
Tube type,
Air-cooled
Tube coiled around Cylinder (Solder Plated)
R290/100 g
Actuator and Reed Switch (T
ime delay controlled)
Float Switch and Solenoid V
alve
6A
Circuit Breaker
Compressor
Internal Thermostat
Pressure Switch (Auto-reset)
Micro switch (Manual-reset)
Shutdown by Microprocessor (Manual-reset)
Net: 66kg (Gross: 76kg)
Carton 746(W) × 706(D) × 887mm(H)
Scoop, Installation Kit
Approx. 26kg - Leveled (Bin Control Setting
Approx. 21kg)
355W (Power Factor: 76%)
Approx. 125kg (Ambient
Temp. 10°C, W
ater
Temp. 10°C)
Approx. 105kg (Ambient
Temp. 21°C, W
ater
Temp. 15°C)
Approx. 82kg (Ambient
Temp. 32°C, W
ater
Temp. 21°C)
Approx. 0.125m
3
(Ambient
Temp. 10
°C
, W
ater
Temp. 10
°C
)
Approx. 0.105m
3
(Ambient
Temp. 21
°C
, W
ater
Temp. 15
°C
)
Approx. 0.082m
3
(Ambient
Temp. 32
°C
, W
ater
Temp. 21
°C
)
Ambient
Temp.: 5-40°C, W
ater Supply
Temp.: 5-35°C
W
ater Supply Pressure: 0.05-0.8MPa,
Voltage Range: Rated V
oltage ±6%
MODEL
POWER SUPPL
Y
AMPERAGE
ELECTRIC CONSUMPTION
ICE PRODUCTION PER 24h
SHAPE OF ICE
W
ATER CONSUMPTION
PER 24h
OUTSIDE DIMENSIONS
HEA
T REJECTION
CABINET
ICE MAKING SYSTEM
W
ATER SUPPL
Y SYSTEM
DRAIN SYSTEM
COMPRESSOR
CONDENSER
EV
APORA
TOR
REFRIGERANT
BIN CONTROL
ICEMAKING W
ATER
CONTROL
REFRIGERANT
CIRCUIT
PROTECTION
REFRIGERANT
CIRCUIT
PROTECTION
MECHANISM PROTECTION
INTERLOCK
WEIGHT
PACKAGE
ACCESSORIES
OPERA
TING
CONDITIONS
MAX. ST
ORAGE CAP
ACITY
*W
e reserve the right to make changes in specifications and design without prior
notice.
1. Install the ice maker properly in accordance with the instructions on location, water
supply/drain connections and electrical connections stated in the instruction and installation manuals provided.
2.
The ice production depends on the ambient and water temperatures. Refer to the instruction manual.
3. Product Code: F1
15
INSULA
TION FOAM
BLOWING AGENT
MALE CONNECT
OR
W
ATER INLET
DRAIN OUTLET
R3/4
ADJUST
ABLE LEGS
289
154
83
674
(547)
24
585
(918)
(333)
AIR
17
AIR
AIR
27
36.5
448
M12
115.5
36
AIR
568
36
89
711
800
640
310
AIR
AIR
AIR
600
(318)
G3/4