25
1-in-1 dr
ain c
ycle
. D
V opens f
or 2 seconds e
ver
y hour
(S1
Dip S
witch 4).
Icemak
er st
atus does not change
.
FD Sequence Flo
w Char
t
LF/S
closed
UF/S
closed
FT
off
WV
o
ff
3.
1
-in-1
2 Dr
ain Cy
cle
& R
estar
t (optional)
3
.
Icemak
er Of
f
UF/S
open
LF/S
open (WV on)
FT
st
ar
ted (90 sec.)
WV
on
CR
contin
ues
Comp
contin
ues
GMR
contin
ues
GM
contin
ues
GMPR
contin
ues
FM
contin
ues
FMR
co
ntin
ues
L
LV
contin
ues
SL
V
contin
ues
1.
Star
tup
2.
Ice P
ur
g
e Cy
cle
WV
on
FT
on (90 sec.)
CR
on
Comp
on
LL
V
on
S
LV
on
GMR
contin
ues
GM
contin
ues
GMPR
contin
ues
FM
contin
ues
FMR
contin
ues
P
ow
er S
witch "ON"
C
ontr
ol S
witch in "ICE"
PO
WER OK LED on
IS Gr
een LED on
IS
Yello
w LED of
f
2.
Infr
ar
ed Sensor Shutdo
wn & R
estar
t
1.
Bin F
ull
IS
activ
at
ed or
DC
st
ar
ts
CR
off
Comp
o
ff
L
LV
o
ff
SL
V
off
GMR
contin
ues
GM
contin
ues
GMPR
contin
ues
FM
contin
ues
FMR
contin
ues
1.
F
ill Cy
cle
3.
F
reez
e Cy
cle
LF/S
closed
UF/S
closed
FT
o
ff
WV
o
ff
CR
co
ntin
ues
Comp
contin
ues
GMR
contin
ues
GM
contin
ues
GMPR
contin
ues
FM
contin
ues
FMR
contin
ues
LL
V
contin
ues
SL
V
contin
ues
Lo
w W
at
er
Saf
ety
UF/S
open
WV
on
FT
ex
ceeded
1-beep
alar
m
sounds
CR
off
Comp
o
ff
LL
V
off
SL
V
off
GMR
contin
ues
GM
contin
ues
GMPR
contin
ues
FM
contin
ues
FMR
contin
ues
DV
on (
DC
onl
y)
GMR
off
GM
o
ff
GMPR
o
ff
FM
off
FMR
off
2
.
Ice P
ur
g
e Cy
cle
10-min.
DT
of
f (
DC
onl
y)
DV
of
f (
DC
onl
y)
1-in-1
2 DT
reset (
DC
onl
y)
IS Gr
een LED on
IS Y
ello
w
LED (fl
ashing or st
eady)
IS dela
y det
er
mined b
y S1 dip s
witch
1, 2, & 3
4.
Icemak
er R
estar
t
5 min
ut
es
Not
e:
If IS f
ails t
o shutdo
wn the
icemak
er
, MBC opens and a
9-beep alar
m sounds
.
4.
Icemak
er R
estar
t
2
.
Ice P
ur
g
e Cy
cle
3
.
1
0-Min
ut
e
Dr
ain
Leg
end:
Comp
-compr
essor
CR
-compr
essor r
ela
y
DC
-dr
ain c
ycle
DT
-dr
ain timer
DV
-dr
ain v
al
ve
FM
-f
an mot
or
FMR
-f
an mot
or
-r
emot
e
FT
-fi
ll timer (lo
w w
at
er saf
et
y)
GM
-gear mot
or
GMPR
-gear mot
or pr
ot
ect r
ela
y
GMR
-gear mot
or r
ela
y (X2 CB)
IS
-infr
ar
ed sensor bin contr
ol
LF/S
-lo
w
er fl
oat s
witch
L
LV
-liquid line v
al
ve (MLH onl
y)
MBC
-mechanical bin contr
ol
PT
-pur
ge timer
S
LV
-suction line v
al
ve (MLH onl
y)
UF/S
-upper fl
oat s
witch
WV
-w
at
er v
al
ve
If F
il
l
> 90 sec.
FT
1-beep alar
m
sounds
WV
contin
ues
W
hen UF/S closes
alar
m r
esets and
2.
Ice P
ur
ge C
ycle st
ar
ts
.
Maxim
um
90
seconds
4.
1
-in-1
2 Dr
ain Cy
cle -
Although the
fact
or
y def
ault 1
-in-1 dr
ain c
ycle
is r
ecommended, a 1
-in-1
2 dr
ain c
ycle is a
vailab
le
. F
or 1
-in-1
2 dr
ain
cy
cle sequence
, see "3.
1
-in-1
2 Hour Dr
ain C
ycle & R
est
ar
t (optional)."
R
efi
ll
F
T Maxim
um
90
seconds
90 sec.
FT
e
xceeded
1-beep alar
m
sounds
90 sec.
PT
begins
W
hen UF/S closes
,
alar
m r
esets and
2.
Ice P
ur
ge C
ycle
st
ar
ts
.
1-beep alar
m
contin
ues
WV
contin
ues
GMR
off
GM
off
GMPR
o
ff
FM
off
FMR
off
IS Gr
een LED on
IS
Yello
w LED of
f
IS Gr
een LED on
I
S
Yello
w LED of
f
1
.
DT Initiat
es DC
To b
ypass
, pr
ess the
"SER
VICE" b
ut
ton af
ter
GM st
ar
ts
.
5 min
ut
es
to "2.
Ice P
ur
ge C
ycle" abo
ve
to "1
. F
ill C
ycle" abo
ve
90
seconds
(S1 dip s
witch 4)
FT
of
f (90 sec.)
FT
e
xceeded
PT
ter
minat
es
30 sec.
GMR
on
GM
on
GMPR
on
FM
on
FMR
on
2. Sequence Flow Chart