9
ENGLISH
SPECIFICATIONS
Model
IM-240ANE
IM-240AWNE
Type
Air-cooled, cube ice
Water-cooled, cube ice
Power Supply
1 phase 220 - 240V 50Hz
1 phase 220 - 240V 50Hz
Electric Consumption
1320W
1300W
Ice Production per 24h
220kg (5mm) / 240kg (15mm)
(ambient temp 10°C, water temp 10°C)
230kg (5mm) / 240kg (15mm)
(ambient temp 10°C, water temp 10°C)
Dimensions
560mm(W) x 700mm(D) x 880mm(H)
560mm(W) x 700mm(D) x 880mm(H)
Refrigerant
R404A, 0.48kg
(GWP: 3920, CO2: 1.882t)
R404A, 0.45kg
(GWP: 3920, CO2: 1.764t)
Insulation Foam Blowing Agent
HFC-free
HFC-free
Weight
Net: 80kg (Gross: 95kg)
Net: 83kg (Gross: 95kg)
Ambient Temp
1 - 40°C
1 - 40°C
Water Supply Temp
5 - 35°C
5 - 35°C
Water Supply Pressure
0.07 - 0.78 MPa (0.7 - 8 bar)
0.07 - 0.78 MPa (0.7 - 8 bar)
Voltage Range
Rated voltage ± 6%
Rated voltage ± 6%
Model
IM-240ANE
IM-240AWNE
Type
Air-cooled, cube ice
Water-cooled, cube ice
Power Supply
1 phase 220 - 230V 60Hz
1 phase 220 - 230V 60Hz
Electric Consumption
1320W
1130W
Ice Production per 24h
220kg (5mm) / 245kg (15mm)
(ambient temp 10°C, water temp 10°C)
215kg (5mm) / 240kg (15mm)
(ambient temp 10°C, water temp 10°C)
Dimensions
560mm(W) x 700mm(D) x 880mm(H)
560mm(W) x 700mm(D) x 880mm(H)
Refrigerant
R404A, 0.55kg
(GWP: 3920, CO2: 2.156t)
R404A, 0.40kg
(GWP: 3920, CO2: 1.568t)
Insulation Foam Blowing Agent
HFC-free
HFC-free
Weight
Net: 80kg (Gross: 95kg)
Net: 83kg (Gross: 95kg)
Ambient Temp
1 - 40°C
1 - 40°C
Water Supply Temp
5 - 35°C
5 - 35°C
Water Supply Pressure
0.07 - 0.78 MPa (0.7 - 8 bar)
0.07 - 0.78 MPa (0.7 - 8 bar)
Voltage Range
Rated voltage ± 10%
Rated voltage ± 10%
Note: The above specifications are for the representative models.
This product includes a hermetically sealed refrigeration system that contains fluorinated greenhouse gases.