7
16) Turn the keg coupler counterclockwise, and remove it from the
cleaning tank.
Keg coupler
Rotary type
Vertical type
Cleaning tank
17) Attach the keg coupler on the keg by turning it clockwise until it
stops.
Keg coupler
Keg
Rotary type
Vertical type
18) Wash the cleaning tank thoroughly, dry it well, and use the cap
provided to shut out dust.
19) Wipe moisture from the beer tap nozzle. Wash the nozzle cap
clean, and fit it on the nozzle. The nozzle cap must be removed
and stored in a clean place during operation.
2. BEER TAP (DAILY)
1) Loosen the union nut of the beer tap by turning it clockwise, and
remove the beer tap.
2) Tilt the beer tap lever toward you, and run tap water through the
beer tap.
3) Refit the beer tap by turning the union nut counterclockwise.
Union nut
Loosen (clockwise)
Tighten (counterclockwise)
3. DRAIN PAN (DAILY)
Wipe the drain pan surfaces by using a cloth containing warm water (30
- 40°C) with invert soap. After 3 minutes, wipe off any remaining soap
with a clean cloth containing cold or warm water. Clean the drain pan
whenever necessary.
1) Remove the drain board, and lift the drain pan to release its
mounting holes from the mounting screws. Be careful not to spill
water and beer collected in the drain pan.
2) Dump water and beer, and wash the drain board and drain pan
with tap water.
3) Lift the drain pan to hook the mounting holes on the mounting
screws, and set the drain board on the drain pan.
4) Check that the overflow hose goes through the hole in the drain
board and can drain water into the drain pan.
Mounting screw
Through hole for
overflow hose
Mounting hole
Overflow hose
Drain board
Drain pan
4. CLEANING BEER CIRCUIT WITH SPONGE (WEEKLY)
IMPORTANT
1. Store the used cleaning sponge for later use.
2. Use the cleaning tank specified by the beer company. Follow
the operating instructions provided on the cleaning tank.
3. Use one of the cleaning sponges provided. To prevent
clogging, do not use more than one sponge or any sponge
other than those provided.
1) Close the beer circuit before flushing.
Rotary type: Turn the keg coupler handle counterclockwise.
Vertical type: Unlock and lift the keg coupler handle all the way
up.
Keg coupler handle
Rotary type
Vertical type
Regulator
Adjust dial
2) Turn the regulator adjust dial counterclockwise to “0”.
3) Shut off the CO2 gas cylinder by turning the main valve clockwise.
4) Move the beer tap lever toward you to dispense beer remaining in
the circuit.
5) When no more beer comes out, move the lever back to its original
position.
6) Loosen the union nut of the beer tap by turning it clockwise, and
remove the beer tap.
7) Loosen the cap nut of the beer tap, and disassemble the beer tap.
Fit the valve shaft in the opposite direction as shown below, and
tighten the cap nut. (This is to prevent the cleaning sponge from
clogging the beer tap.)