background image

DRAFT BEER DISPENSER                                 

DBF-25SB-AU 

DBF-43SB-AU

INSTRUCTION MANUAL 

L168QU111 (062012)

Summary of Contents for DBF-25SB-AU

Page 1: ...DRAFT BEER DISPENSER DBF 25SB AU DBF 43SB AU INSTRUCTION MANUAL L168QU111 062012 ...

Page 2: ... pcs Chain 1 pc Beer hose adaptor 1 pc Drain pan 1 pc Drain board 1 pc Nozzle cap 3 pcs O ring P10A 1 pc O ring P21 1 pc 2 UNPACKING AND LOCATION CAUTION 1 To prevent injury wear work gloves and hold the bottom panel to carry the unit Work in a pair or group 2 The location should provide a firm and level foundation for the equipment to avoid the risk of water leaks or injury caused by overturn or ...

Page 3: ...ontains CO2 gas to prevent beer from becoming flat and to push beer out of the keg Consult with the liquor shop or beer company and prepare a proper CO2 gas cylinder intended for use with beer 9 Cylinder chain accessory Securely retain the CO2 gas cylinder on the fixed hook 10 Hook accessory Mount on a firm base with the screws provided 11 Regulator Adjusts CO2 gas pressure in the cylinder for pro...

Page 4: ...nect and reinsert the gas hose Cut it about 20 mm before reuse 3 Cut the hose end vertically insert it securely into the quick joints and check for gas leaks Quick gas hose joint 1 To insert the gas hose into the quick joint push it all the way in 2 To disconnect the gas hose from the quick joint push it with fingers as shown below and pull it out Quick joint Gas hose d EXTERNAL BEER LINE 1 Attach...

Page 5: ...ANT 1 Wash the keg joint with water if necessary 2 Do not loosen the ferrule on the keg 5 Turn the regulator adjust dial clockwise to the appropriate gas pressure level specified by the beer company 4 Attach the keg coupler on the new keg by turning it clockwise Keg coupler handle Rotary type Vertical type Regulator Adjust dial Keg coupler Keg Rotary type Vertical type Regulator Adjust dial Keg co...

Page 6: ... nozzle end Wash the nozzle cap clean and fit it on the nozzle The nozzle cap must be removed and stored in a clean place during operation Fit on Beer tap Nozzle Nozzle cap 1 Tilt a clean mug at an angle of 45 and place its inner surface in contact with the liquid nozzle of the beer tap 2 Pull the beer tap lever toward you to dispense beer over the inner surface of the mug 3 After dispensing a spe...

Page 7: ...coupler handle clockwise until it stops Vertical type Push down the keg coupler handle until it locks in place 12 Check if the cleaning tank is provided with a siphon tube inside If no siphon tube is provided Turn down the ferrule of the cleaning tank upside down If siphon tube is provided Turn up the ferrule of the cleaning tank 13 Prepare a plastic bucket to receive cleaning water Move the beer ...

Page 8: ...ter 3 Lift the drain pan to hook the mounting holes on the mounting screws and set the drain board on the drain pan 4 Check that the overflow hose goes through the hole in the drain board and can drain water into the drain pan Mounting screw Through hole for overflow hose Mounting hole Overflow hose Drain board Drain pan 4 CLEANING BEER CIRCUIT WITH SPONGE WEEKLY IMPORTANT 1 Store the used cleanin...

Page 9: ...ning tank 22 Attach the keg coupler on the keg Keg coupler handle Rotary type Vertical type Keg coupler Rotary type Vertical type Cleaning tank 19 Recover the cleaning sponge from the bucket 20 Repeat the above steps 10 to 16 until clear water comes out of the beer tap 21 Remove the beer tap set the valve shaft in its normal position and refit the beer tap on the unit Keg coupler Keg Rotary type V...

Page 10: ...d you Push it down and pull it out 3 Wash the air filter with cold water or warm water containing a neutral dishwashing detergent Be careful not to break the net After using a detergent rinse the air filter thoroughly Dry it in the shade Drain pan Air filter 4 Fit the air filter into the filter guide at the bottom and slide it to the back 5 Refit the drain pan IMPORTANT 1 When the air filter is cl...

Page 11: ...er tank according to I 5 a COOLING WATER SUPPLY 7 Refit the top cover and inner cover 8 Plug in the unit IMPORTANT Dust bacteria and moisture in the air may cause contamination or reduction in conductivity of the cooling water To prevent clogging of the overflow hose or inadequate ice storage refresh the cooling water twice a year If the cooling water conductivity reduces and no ice is produced in...

Reviews: