![Hoshizaki AM-50BAJ Instruction Manual Download Page 33](http://html1.mh-extra.com/html/hoshizaki/am-50baj/am-50baj_instruction-manual_2164898033.webp)
33
6) Move the control switch to the "WASH" position.
7) Allow the cleaning solution to circulate for 30 minutes, then move the control switch to
the "OFF" position.
8) Disconnect the suction tube. Allow the water tank to drain, then reconnect the suction
tube.
9) Move the control switch to the "ICE" position and allow the icemaker to operate for
2 minutes. This allows the water tank to fill with water.
10) Move the control switch to the "WASH" position.
11) Allow the water to circulate for 5 minutes, then move the control switch to the "OFF"
position.
12) Disconnect the suction tube. Allow the water tank to drain, then reconnect the suction
tube.
13) Repeat steps 9 through 12 three more times to rinse thoroughly.
3. Sanitizing Solution
Dilute 0.5 fl. oz. (14.8 ml or 1 tbs) of a 5.25% sodium hypochlorite solution (chlorine
bleach) with 1 gallon (3.8 l) of warm water. This is a minimum amount. Make more
solution if necessary. Using a chlorine test strip or other method, confirm that you have a
concentration of about 200 ppm.
IMPORTANT! For safety and maximum effectiveness,
use the solution immediately after dilution.
4. Sanitizing Procedure
1) Make sure the control switch is in the "OFF" position and the ice storage bin is empty.
2) Remove the slope from the ice storage bin by carefully bending it in the center and
releasing it from the 2 slope shafts. See Fig. 37.
3) Remove each separator by lifting it to the horizontal position and pushing it hard inward.
See Fig. 38.
Separator
Slope
Fig. 37
Fig. 38
Slope Shafts