2
Installation
Means of disconnection from the supply having at least 3mm contact separation in both
poles must be incorporated in the fixed wiring.
We recommend a separate fused circuit from the consumer unit (24 Hour supply)
protected by a 15 amp HRC fuse or, preferably a 16 amp MCB. In some cases immersion
heater failure can damage the Electrisaver. Installation of a 100 mA RCD will provide
additional protection for the unit. If the Electrisaver is to be connected to a ring main then
the spur feeding the controller should be protected in the same way.
The Electrisaver is NOT suitable for
mounting on an unearthed metal
surface.
Surface Wall Mounting
The Electrisaver is suitable for
mounting directly on to any surface
mounted single gang moulded box
having a minimum depth of 28mm.
Cable entry being through the most
convenient cut-out.
Flush Wall Mounting
The Electrisaver can be mounted
directly to any standard 35mm deep
flush mounting single gang wiring
box complying with BS4662
THE ELECTRISAVER SHOULD BE KEPT IN ITS SEALED PACK UNTIL ALL DUST AND DEBRIS HAVE
BEEN CLEARED AWAY PRIOR TO MAKING CONNECTIONS.