background image

2

Installation

Means of disconnection from the supply having at least 3mm contact separation in both 
poles must be incorporated in the fixed wiring.
We recommend a separate fused circuit from the consumer unit (24 Hour supply) 
protected by a 15 amp HRC fuse or, preferably a 16 amp MCB. In some cases immersion 
heater failure can damage the Electrisaver. Installation of a 100 mA RCD will provide 
additional protection for the unit. If the Electrisaver is to be connected to a ring main then 
the spur feeding the controller should be protected in the same way. 
The Electrisaver is NOT suitable for 
mounting on an unearthed metal 
surface.

Surface Wall Mounting

The Electrisaver is suitable for 
mounting directly on to any surface 
mounted single gang moulded box 
having a minimum depth of 28mm. 
Cable entry being through the most 
convenient cut-out.

Flush Wall Mounting

The Electrisaver can be mounted 
directly to any standard 35mm deep 
flush mounting single gang wiring 
box complying with BS4662

THE ELECTRISAVER SHOULD BE KEPT IN ITS SEALED PACK UNTIL ALL DUST AND DEBRIS HAVE 

BEEN CLEARED AWAY PRIOR TO MAKING CONNECTIONS.