background image

T

Th

he

e  s

siim

mp

plle

e  iin

ns

st

tr

ru

uc

ct

tiio

on

ns

s  b

be

ello

ow

w  a

ar

re

e  d

de

es

siig

gn

ne

ed

d  t

to

o  h

he

ellp

p  w

wiit

th

h  t

th

he

e  p

pr

ro

og

gr

ra

am

mm

miin

ng

g  o

of

f  t

th

he

e  u

un

niit

t..  A

Allll  t

th

he

e  f

fo

ollllo

ow

wiin

ng

g

iin

ns

st

tr

ru

uc

ct

tiio

on

ns

s  r

re

eq

qu

uiir

re

e  t

th

he

e  f

fr

ro

on

nt

t  f

flla

ap

p  t

to

o  b

be

e  llo

ow

we

er

re

ed

d..  P

Plle

ea

as

se

e  r

re

ep

plla

ac

ce

e  t

th

he

e  f

flla

ap

p  w

wh

he

en

n  

n

no

or

rm

ma

all  o

op

pe

er

ra

at

tiio

on

n  iis

s  r

re

eq

qu

uiir

re

ed

d..

Electronic equipment can in some circumstances be affected by electrical interference. If the

programmer’s display becomes frozen or scrambled; or if you wish to revert back to the default time 

settings please use the following procedure.

F

FR

RO

ON

NT

T  C

CO

OV

VE

ER

R

S

SE

ET

TT

TIIN

NG

G  T

TH

HE

E  T

TIIM

ME

E  O

OF

F  D

DA

AY

Y

S

SE

ET

TT

TIIN

NG

G  T

TH

HE

E  O

ON

N  A

AN

ND

D  O

OF

FF

F  T

TIIM

ME

ES

S  

The normal working position for the SET switch is in the PROG.RUN position. In order to remind the user

of this, the flap is unable to be closed with the switch in any other position.

Move the SET

switch to the CLOCK

position.

Use PLUS and

MINUS buttons to

adjust time

Return SET switch to

PROG.RUN position

Move SET switch

to either WATER or 

HEATING position.

Use the PLUS

and MINUS

buttons to adjust

the 1st ON  time.

Use the PLUS and

MINUS buttons to

adjust the 1st OFF

time.

Repeat this

process for 2nd and

3rd settings.

Return SET switch

to PROG.RUN 

position.

Press

ENTER

Press

ENTER

R

RE

ES

SE

ET

TT

TIIN

NG

G  T

TH

HE

E  P

PR

RO

OG

GR

RA

AM

MM

ME

ER

R

The SET slide switch must be in the PROG.RUN position for the following instructions.

The following actions work independently on either Hot Water or Central Heating.

Press SELECT once.

Programme goes from

AUTO to ALL DAY

Press SELECT again.

Programme goes from

ALL DAY to ON

Press SELECT again.

Programme goes from

ON to OFF

Press SELECT again.

Programme goes from

OFF to AUTO

Channel will operate

from first ON until last

OFF period 

Channel will be

continuously ON

Channel will be

continuously OFF

Programmer will return

to normal ON and OFF

times

B

BO

OO

OS

ST

T  F

FU

UN

NC

CT

TIIO

ON

N

-

-

1

1  o

or

r  2

2  h

ho

ou

ur

r  t

te

em

mp

po

or

ra

ar

ry

y  o

ov

ve

er

rr

riid

de

e

Press BOOST button

once for 1 hour of

Hot Water or

Central Heating

Press BOOST button

twice for 2 hours of

Hot Water or

Central Heating

At any time during a BOOST

period press BOOST again to

return to normal programming

A

AD

DV

VA

AN

NC

CE

E  F

FU

UN

NC

CT

TIIO

ON

N

-

-  

B

Br

riin

ng

gs

s  f

fo

or

rw

wa

ar

rd

d  n

ne

ex

xt

t  o

on

n  o

or

r  o

of

ff

f  o

op

pe

er

ra

at

tiio

on

n

Press ADVANCE button once

to move to the next

ON/OFF time

To cancel the advance press the ADVANCE

button again. This will return the unit to

its normal programme

H

HO

OL

LIID

DA

AY

Y  F

FU

UN

NC

CT

TIIO

ON

N  

-

-  

A

Allllo

ow

ws

s  s

sy

ys

st

te

em

m  t

to

o  b

be

e  p

pr

ro

og

gr

ra

am

mm

me

ed

d  f

fo

or

r  u

up

p  t

to

o  3

32

2  d

da

ay

ys

s

Move SET switch to the

HOLIDAY position

Use the PLUS button to enter the

required number of nights

(MAX OF 32 NIGHTS)

Return SET switch to the

PROG.RUN position 

Whilst the HOLIDAY FUNCTION is in operation the system will remain OFF, the display will show the 

number of nights remaining. The HOLIDAY setting is an instant function and cannot be set in advance.

The HOLIDAY FUNCTION can be cancelled at any time by pressing any of the SELECT buttons. Normal 

programme functions will resume at the first ON period after the pre-set number of nights has expired.

IIN

NF

FO

OR

RM

MA

AT

TIIO

ON

N  A

AN

ND

D  A

AD

DV

VIIC

CE

E

Programming ON/OFF times

If a Heating or Hot water period is not required it can be cancelled by setting the ON and OFF

settings to the same time. Example ON 10:00am  OFF 10:00am

Your programmer will prevent you from accidentally overlapping ON and OFF times. 

Example: If the 2nd ON time is set at 12:00pm and then you try and set the 1st OFF at 12:30 pm the

OFF setting will ‘bounce’ by a 10 minute period until the 2nd ON time has been adjusted.

12:OO

PM

SETTING

1:45

PM

SET

SETTING 1ST

ON

OFF

6:30

AM

8:30

AM

08

SETTING

10:30

AM

BOOST 1 2

AUTO                 AUTO

ON UNTIL           ON UNTIL

10:00

AM

10:00

AM

10:00

AM

AUTO                 AUTO

ON UNTIL           ON UNTIL

10:00

AM

AUTO

ON UNTIL

10:30

AM

AUTO

ON UNTIL

10:30

AM

AUTO

ON UNTIL

10:30

AM

ALL DAY

ON UNTIL

8:30

PM

ON

OFF

ADVANCE

SELECT

Lower the front flap of the unit. On the Heating channel press the

ADVANCE and SELECT buttons together then release the buttons and

the programmer will return to the preset factory settings. 

P

Pa

ag

ge

e  2

2

BOOST

S

SP

PE

EC

CIIA

AL

L  F

FE

EA

AT

TU

UR

RE

ES

S

P

Pa

ag

ge

e  3

3

Should you encounter any problems, please refer to the

Q

Qu

ue

es

st

tiio

on

n  a

an

nd

d  A

An

ns

sw

we

er

r  section located on page 4

1

st 

ON 1

st 

OFF

2

nd 

ON

2

nd 

OFF

3

rd 

ON

3

rd 

OFF

6:30 

A

AM

M

8:30 

A

AM

M

12:00 

P

PM

M

12:00 

P

PM

M

4:30 

P

PM

M

10:30 

P

PM

M

D

DE

EF

FA

AU

UL

LT

T  T

TIIM

ME

E  S

SE

ET

TT

TIIN

NG

GS

S

The default factory settings are shown above, however if you wish to change these proceed as 

instructed below.

RESE

T

On the ChannelPlus display - Boost 1 is Hot water extension 1 or 2 hour and Boost 2 is Heating extension 1 or 2 hours

Reviews: