background image

Short Instruction for Filling LEEB LT and GS Variant ECO

1.  Open left side cover, connect suction hose 

with filling connection and open filling valve.

Filling connection

Filling valve

The illustration 

shows:

Leeb LT

2.  Set the ball valve on the suction and pressure 

side to filling.

Ball valve 

pressure side

Ball valve 

suction side

3.  Start the tractor

 

¾

Turn on the PTO-shaft with approx. 540 rpm.

4.  

Observe the filling level of the solution tank 

and turn off the PTO-shaft when the desired 

filling level or the rated volume have been 

reached. Interruption is possible at any time 

by switching off the PTO-shaft.

Solution tank 

filling level

5.  

Close the filling valve, take off suction hose 

and close side cover.

 

NOTE

The short instruction for the operation of the machine is only to be used with observation of the 

safety and warning notes of the pertaining operating instructions. Compensation claims for dam

-

ages due to non-observance of the operating instructions are excluded.

Art.: 80900223