background image

Art.: 80900223

Short Instruction for Filling LEEB LT and GS Variant CCS

1.  Start the tractor 

 

¾

Set the diesel speed to approx. 1500 rpm.

2.  Open left side cover, connect suction hose 

with filling connection and open filling valve.

Filling connection

Filling valve

The illustration 

shows:

Leeb LT

3.  Set the ball valve on the suction and pressure 

side to filling.

Ball valve 

pressure side

Ball valve 

suction side

4.  On the terminal

 

¾

Enter the filling limit

 

¾

Start filling

Stop

Filling

start

pulling suction

Filling limit

enter

Filling  stops  automatically  when  the  desired 

value has been reached. Interruption via the 

stop button is possible at any time.

 

¾

Or start filling (without filling limit) by switching 

on the pump on the external control terminal 

Mini. Interruption is possible at any time by 

switching off the pump.

Switch on the pump

5.  

Close the filling valve, take off suction hose 

and close side cover.

 

NOTE

The short instruction for the operation of the machine is only to be used with observation of the 

safety and warning notes of the pertaining operating instructions. Compensation claims for dam

-

ages due to non-observance of the operating instructions are excluded.