Art.: 80900223
Short Instruction for Filling LEEB LT and GS Variant CCS
1. Start the tractor
¾
Set the diesel speed to approx. 1500 rpm.
2. Open left side cover, connect suction hose
with filling connection and open filling valve.
Filling connection
Filling valve
The illustration
shows:
Leeb LT
3. Set the ball valve on the suction and pressure
side to filling.
Ball valve
pressure side
Ball valve
suction side
4. On the terminal
¾
Enter the filling limit
¾
Start filling
Stop
Filling
start
pulling suction
Filling limit
enter
Filling stops automatically when the desired
value has been reached. Interruption via the
stop button is possible at any time.
¾
Or start filling (without filling limit) by switching
on the pump on the external control terminal
Mini. Interruption is possible at any time by
switching off the pump.
Switch on the pump
5.
Close the filling valve, take off suction hose
and close side cover.
NOTE
The short instruction for the operation of the machine is only to be used with observation of the
safety and warning notes of the pertaining operating instructions. Compensation claims for dam
-
ages due to non-observance of the operating instructions are excluded.