MAN0893-02-EN
Specifications / Installation
________________________________________________________________________________________________________________________________________
Feb 2, 2010
Page 2 of 5 #1039
3.
Panel Cut out and dimensions
Refer to the QX351 User Manual (MAN0892) for panel box information and a handy checklist of requirements.
4.
Ports and Connectors
Note: The tolerance to meet NEMA standards is
±
0.005” (0.1 mm).
Note: Max. Panel thickness: 5 mm
6.875”
[175mm]
[131mm]
001OCS003-R1
5.156”
R .125” [3 mm] TYP.
RADIUS CORNERS
WHEN REQUIRING
DUST OR WATER
TIGHT SEAL PER
NEMA 4, 4X OR 12
Removable Media
USB B
Battery Cover
Ethernet
USB A
FOX I/O
USBA:
For flash drive connectivity
USBB:
For network communication and
programming of OCS
FOX I/O:
For backplane extension
Removable Media:
Uses Removable Memory for data logging,
screen captures, program loading and
recipes. Horner Part No.: HE-MC1
Serial Communications:
MJ1/MJ2: (RS-232 / RS-485) Use for
Cscape programming and Application-
Defined Communications.
Ethernet:
Used for Cscape programming and
Application-Defined Communications.