background image

MAN0893-02-EN  

                                                                                                                       Specifications / Installation 

________________________________________________________________________________________________________________________________________
Feb 2, 2010 

            Page 2 of 5                                                                                                                                       #1039 

 

3. 

Panel Cut out and dimensions 

 

 
        Refer to the QX351 User Manual (MAN0892) for panel box information and a handy checklist of requirements. 

 
 
 
 
 

 
 

 

 
 

4. 

Ports and Connectors 

 

 

 

 
 

 

 
 
 
 
 
 

Note:   The tolerance to meet NEMA standards is  

±

 0.005” (0.1 mm). 

Note:  Max. Panel thickness: 5 mm 

6.875”

[175mm]

[131mm]

001OCS003-R1

5.156”

R .125” [3 mm] TYP.
RADIUS CORNERS
WHEN REQUIRING

DUST OR WATER

TIGHT SEAL PER

NEMA 4, 4X OR 12

Removable Media 

USB B 
 

Battery Cover 

Ethernet 
 

USB A 

FOX I/O 
 

USBA:  
For flash drive connectivity 
 
USBB:  
For network communication and 
programming of OCS 
 
FOX I/O:  
For backplane extension 
 
Removable Media:   
Uses Removable Memory for data logging, 
screen captures, program loading and 
recipes. Horner Part No.:  HE-MC1 
 
 
Serial Communications: 
MJ1/MJ2:
  (RS-232 / RS-485) Use for 
Cscape programming and Application-
Defined Communications. 
 
 
Ethernet:  
Used for Cscape programming and 
Application-Defined Communications. 

Summary of Contents for QX351 Series

Page 1: ... Supports upto 2 smartstacks Fiber Optic Extension System FOX Extends a high speed QX backplane enabling SmartStack I O Modules to be mounted several meters from the QX The FOX also significantly increases the number of SmartStack I O modules supported by one QX SmartStix Modules It is a family of remote I O products for the QX Serial Ports 2 Serial Ports RS232 RS485 Ethernet Ethernet 10 100 Mbps ...

Page 2: ...Panel thickness 5 mm 6 875 175mm 131mm 001OCS003 R1 5 156 R 125 3 mm TYP RADIUS CORNERS WHEN REQUIRING DUST OR WATER TIGHT SEAL PER NEMA 4 4X OR 12 Removable Media USB B Battery Cover Ethernet USB A FOX I O USBA For flash drive connectivity USBB For network communication and programming of OCS FOX I O For backplane extension Removable Media Uses Removable Memory for data logging screen captures pr...

Page 3: ...MJ2 Pins Signal Direction Signal Direction 8 TXD OUT TXD OUT 7 RXD IN RXD IN 6 0 V Ground 0 V Ground 5 5 60mA OUT 5 60mA OUT 4 RTS OUT TX OUT 3 CTS IN TX OUT 2 RX TX IN OUT RX IN 1 RX TX IN OUT RX IN 1 8 Pin MJ2 Pins Signal Direction 8 TXD OUT 7 RXD IN 6 0 V Ground 5 5 60mA OUT 4 TX OUT 3 TX OUT 2 TX RX IN OUT 1 TX RX IN OUT 1 8 MJ2 Half Duplex Mode 5V 60mA Max Pin MJ2 Pins Signal Direction 8 TXD ...

Page 4: ...ion Direction 1 V CAN Ground 2 CN_L CAN Data Low In Out 3 SHLD Shield Ground 4 CN_H CAN Data High In Out 5 NC No Connect Primary Power Port Pins Pin Signal Description 1 Ground Frame Ground 2 V Input Power Supply Ground 3 V Input Power Supply Voltage As seen when looking at the side of the QX351 unit The DIP Switches are used for termination of the RS 485 ports The QX351 is shipped un terminated T...

Page 5: ...struction and operation of this equipment and the hazards involved should install adjust operate or service this equipment Read and understand this manual and other applicable manuals in their entirety before proceeding Failure to observe this precaution could result in severe bodily injury or loss of life This device complies with part 15 of the FCC Rules Operation is subject to the following two...

Reviews: