CALIBRATION

•  For optimal performance, turn 

unit on and allow 5-15 minutes to 

warm up.

•  Verify powder pan has been 

removed, and that the red scale 

plate is empty.

•  Press 

ZERO/CALIBRATE

 button for 

three seconds until unit displays 

“CAL ---“

.

•  When 

10.00g

 is flashing, place 

the 10g weight on the center of 

the scale plate. The unit will show 

“---- --”

 while calibrating the 

10g weight.

•  When 

10.00g

 appears again, 

remove the weight.

•  When 

50.00g

 is flashing, place 

the 50g weight on the center of 

the scale plate. The unit will show 

“---- --” while calibrating the 

50g weight.

•  When 

50.00g

 appears again, 

remove the weight

•  After calibration, the unit will 

briefly display 

“PASS”

 before 

returning to normal operation.

6

Summary of Contents for AUTO CHARGE PRO

Page 1: ...Item No 050053 INSTRUCTIONS AUTO CHARGE PRO...

Page 2: ...r or eventually attack the plastic Remove powder after every loading session Internal components are very sensitive Do not shake drop or overload unit Handle unit with care treating it as the sensitiv...

Page 3: ...Hopper Lid Powder Empty Spout 50g Calibration Weight 10g Calibration Weight 220V Plug Converter 9V Power Supply US Plug Adapter EURO Plug Adapter Brush Draft Cover Bubble Level Leveling Feet LCDTouch...

Page 4: ...rear right side is closed Fill clear powder hopper until powder is visible at bottom of clear hopper Fill higher if loading many rounds Check to be sure that Setting reads Normal Tap TARGET button in...

Page 5: ...g target amount hold to trickle AUTO MANUAL Tap to switch from AUTO to MANUAL mode AUTO Dispensing cycle begins once empty pan is placed back on scale plate and scale re zeros itself MANUAL Use DISPEN...

Page 6: ...NG to toggle between Normal 1 2 3 4 The settings you are currently using are displayed above the SETTING button Settings 1 2 3 4 are memory slots for any custom settings When Target Speed Time and Pro...

Page 7: ...00g is flashing place the 10g weight on the center of the scale plate The unit will show while calibrating the 10g weight When 10 00g appears again remove the weight When 50 00g is flashing place the...

Page 8: ...owder is out of the trickle tube repeat steps 1 and 2 to remove the rest of the powder At this time remove the powder hopper and use the included brush to clean out the rest of the powder from the hop...

Reviews: