background image

QUICK START

•  Verify unit is properly assembled with scale plate, powder pan, and clear powder 

hopper in place.

•  Turn unit on by removing the powder pan, plugging it in and pressing black power 

button on front of unit. For best performance, allow unit to stabilize for 5-15 

minutes before use.

•  Calibration is recommended before each use. (See Calibration Section.)
•  Ensure powder pan is on scale and that actual weight reading (right side of 

display) reads 

“0.0.”

 If not, touch 

ZERO/CALIBRATE

 button.

•  Verify that powder hopper empty nozzle (at rear, right side) is closed. Fill clear 

powder hopper until powder is visible at bottom of clear hopper. Fill higher if 

loading many rounds.

•  Check to be sure that “Setting” reads “Normal.”
•  Tap 

TARGET

 button in upper left corner.

•  Enter Target Weight using numerical keypad. Last number entered should be 

decimal amount of charge: 

xx.X.

 Press 

ENTER

 to store Target Weight.

•  Tap

 DISPENSE

 to begin dispensing entered powder charge.

•  Should dispensed charge be greater than 0.1 of a grain above targeted amount, 

“OVER”

 will be displayed. Press 

ENTER 

to remove 

“OVER”

 warning. Then, either 

dump charge into powder tube and re-dispense or remove a small amount of 

powder, and press and hold 

DISPENSE

 to trickle to desired weight.

•  Do not use 

“OVER” 

charges.

3

Summary of Contents for AUTO CHARGE PRO

Page 1: ...Item No 050053 INSTRUCTIONS AUTO CHARGE PRO...

Page 2: ...r or eventually attack the plastic Remove powder after every loading session Internal components are very sensitive Do not shake drop or overload unit Handle unit with care treating it as the sensitiv...

Page 3: ...Hopper Lid Powder Empty Spout 50g Calibration Weight 10g Calibration Weight 220V Plug Converter 9V Power Supply US Plug Adapter EURO Plug Adapter Brush Draft Cover Bubble Level Leveling Feet LCDTouch...

Page 4: ...rear right side is closed Fill clear powder hopper until powder is visible at bottom of clear hopper Fill higher if loading many rounds Check to be sure that Setting reads Normal Tap TARGET button in...

Page 5: ...g target amount hold to trickle AUTO MANUAL Tap to switch from AUTO to MANUAL mode AUTO Dispensing cycle begins once empty pan is placed back on scale plate and scale re zeros itself MANUAL Use DISPEN...

Page 6: ...NG to toggle between Normal 1 2 3 4 The settings you are currently using are displayed above the SETTING button Settings 1 2 3 4 are memory slots for any custom settings When Target Speed Time and Pro...

Page 7: ...00g is flashing place the 10g weight on the center of the scale plate The unit will show while calibrating the 10g weight When 10 00g appears again remove the weight When 50 00g is flashing place the...

Page 8: ...owder is out of the trickle tube repeat steps 1 and 2 to remove the rest of the powder At this time remove the powder hopper and use the included brush to clean out the rest of the powder from the hop...

Reviews: