![Horizont 10895 Instruction Manual Download Page 3](http://html1.mh-extra.com/html/horizont/10895/10895_instruction-manual_2163459003.webp)
4
5
birdy A 10895
2. Determine the correct angle of inclination for the solar panel.
The position of the sun above the horizon changes during the seasons. As
a general recommendation, an angle of 50 degrees is optimal for long-term
use in most parts of Europe. Nevertheless, the angle can be adjusted condi-
tional upon the season to optimize the output of the solar panel for recharg-
ing the rechargeable battery (see Fig. below). The steeper the angle of
inclination, the greater the cleaning effect during rain or snow
Recommended setting angle of the panel
South Europe / North Africa (South CH & A)
Winter
Nov. - Feb.
Spring
Mar. & Apr.
Summer
May & Aug.
Fall
Sept. & Oct.
50°
43°
36°
It may be the case that in winter (except for southern Europe) there are not
enough hours of sunshine to fully charge the rechargeable battery.
3. Regularly remove any deposits and dirt from the solar panel
This includes removing dust leaves and snow, since these can reduce the
performance of the module for recharging the rechargeable battery.
Only check the rechargeable battery indicator in solar operation at dawn
(without sunlight).
WARNING:
Do not leave the switched off device in the sun with a rechargeable
battery and a solar panel for a longer period. Why?
This could damage the rechargeable battery.
4. Energizer Operating Description
Solar operation:
The solar panel produces electricity as soon as it is exposed to usable sunlight. The pasture fencer constantly requires elec-
tricity - by day as well as by night. The electricity generated in this way by the panel is stored in a rechargeable 12V battery,
which means the energizer can operate without sunlight. The solar panel may not always have a sufficiently large output
to fully recharge a rechargeable battery – especially in dark, grey and misty months (e.g. October to
February).
The energizer is operated primarily from the solar panel. If the solar panel does not have sufficient output,
the energizer switches automatically to the connected 12 volt rechargeable battery.
Rechargeable battery indicator:
The rechargeable battery indicator provides information about the rechargeable battery or battery voltage. The solar display
lights up constantly in green when the solar panel charging voltage is greater than the voltage of the rechargeable battery/
battery. Whilst the solar panel charges the 12V rechargeable battery.
5. Maintenance
Table 13 (12V rechargeable battery)
Remaining capacity
Flashing light green
40-100%
Rechargeable battery good
Flashing light red/
green
20-40%
Charge the battery
Flashing light red
Rechargeable battery depleted
Fast flashing
light
red
Rechargeable battery, exchange
recommended
The rechargeable battery must be recharged at the latest when discharged down to 20% (only 80% charge capacity left) to
prevent deep discharge damage. The rechargeable battery indicator (LED2) lights up:
Do note that temperature and measurement deviation may cause these figures to vary.
Caution!
When using a solar system
Only carry out a battery or rechargeable battery test at start of the day ( no solar power supplied - cover panel )
6. Disassembly, Dismantling, Storage and Transport
Disassembly, Dismantling
Before starting disassembly:
●
Switch off energizer
●
Disconnect entire energy supply from the energizer.
●
Remove operating/auxiliary materials and any remaining working materials and dispose of in an environmentally-compati-
ble manner.
Then properly clean sub-assemblies and parts and disassemble them in taking account of the local industrial safety &
environmental protection provisions in force.
Storage, Transport
Ensure that the energizer is both stored and transported only when switched off.
NOTE!
Ensure that rechargeable batteries are stored in ventilated and dry rooms.
7. Faults and Repairs
WARNING!
Repairs may only be carried out by qualified persons.
Only the spare parts prescribed by the manufacturer may be used.
Subject to technical alterations!
Table 14
Faults
Display
Corrective action
Rechargeable battery under
40% capacity
LED flashes alternately red/green
Charge the battery
Rechargeable battery under
20% capacity
LED flashes red
Charge the battery
Rechargeable battery under
10% capacity
LED rapidly flashes red
Exchange battery
Check solar panel alignment
10-20%