28/02/2019
Ver. 25
1.
The speed controller will be set on high, as default from the factory
2.
Depending on the flue run, fan speed can be turned down to reduce noise pollution into the
room.
3.
The speed controller is located on the control board, on the left hand side of the fireplace.
4.
Always start the fire with the fan on high and let run for 5 minutes to make sure the burner does
not cut out.
5.
To reduce the fan speed, turn the speed controller anti-clockwise, only turn in small quarter
increments. After each turn wait 30 seconds. This will give the fan and burner pressure time to
equalise.
6.
When you have turned the speed controller too low the main burner will switch off. You will need
to increase the speed by a quarter turn, wait until the main burner re- ignites. Let it run for 2-5
minutes. If the main burner stays consistent, you will have reached your minimum fan speed.
Turn fan speed
controller
switch counter
clockwise to
decrease fan speed
Turn fan speed
controller
switch clockwise to
increase fan speed
Fan
speed
controller
switch
POWER FLUE FAN SPEED CONTROL
ADJUSTMENT INSTRUCTION
Installation Instructions Kemlan Power Flue Horizon Gas Fireplaces
25