HORITA TR-100 Series User Manual Download Page 6

 

NOTE: 

 

Make sure the plug is inserted all the way into the power connector or else damage to the power adapter may result.  
Do not use an adapter of more than 9 volts at 500 milliamperes or damage to the TR-100 may result. 

 

4.2  Connecting LTC In and Out 

Figure 4-1 shows a basic hookup for the TR-100. 
 

VCR

TR-100

 IN  LTC 

LTC OUT 

LTC OUT

As Required

MIDI Out

As Required

 

 

Figure 4-1, Basic TR-100 Hookup

 

 
Connect SMPTE LTC from its source to the RCA connector labeled LTC IN.  Reshaped, 2V P-P LTC is available at 
the RCA connector labeled LTC OUT. 
 

4.3  Connecting MIDI Out 

Use a standard 5-pin DIN MIDI cable to connect the TR-100 MIDI time code output to your MIDI equipment as 
desired. 

 

 OPERATING THE TR-100 

 

5.1  Controlling the Display 

 

The TR-100 rear panel DATA switch allows the display of either time code or user bits. 
 
The FRAMES switch allows the frame number display to be turned on or off. This only applies when displaying  
time code. When user bits are displayed, the FRAMES switch is disabled. 
 
The BRIGHT knob controls the display brightness. 
 

5.2  Display Description 

The following paragraphs refer to Figure 5-1 when describing various aspects of the TR-100 display. 
   

                                

DF

12:35:23:09

12:35:23:09

HRS

MIN

SEC

FRM

LTC PRESENT

 

 

Figure 5-1, TR-100 LED Display 

 

Summary of Contents for TR-100 Series

Page 1: ...HORITA TR 100 USER MANUAL MULTI FRAME RATE SMPTE TIME CODE READER WITH LED DISPLAY Doc 073129 00 Rev B C Copyright 2014 P O Box 3993 Mission Viejo CA 92690 949 489 0240 www horita com...

Page 2: ...ny form or by any means without prior written consent of HORITA CO P O Box 3993 Mission Viejo CA 92690 HORITA CO makes no warranties with respect to this documentation and disclaims any warranties of...

Page 3: ...Time Code 5 CONNECTING THE TR 100 5 4 1 Connecting Power 5 4 2 Connecting LTC In and Out 6 4 3 Connecting MIDI Out 6 OPERATING THE TR 100 6 5 1 Controlling the Display 6 5 2 Display Description 6 5 3...

Page 4: ...nt and drop frame or non drop frame time code Reads 23 976 24 film 25 PAL 29 97 drop frame non drop frame NTSC and 30 FPS frames per second time codes and displays the frame rate of the code being rea...

Page 5: ...e Code Drop frame time code is a form of SMPTE code which is used when it is important that the time code time value also be an accurate representation of real time Drop frame is not used for the 25 F...

Page 6: ...beled LTC OUT 4 3 Connecting MIDI Out Use a standard 5 pin DIN MIDI cable to connect the TR 100 MIDI time code output to your MIDI equipment as desired 5 OPERATING THE TR 100 5 1 Controlling the Displ...

Page 7: ...at play speed For reference the complete MTC full frame message format is in hex F0 7F 7F 01 01 hr mn sc fr F7 for the time code value and for the user bit value F0 7F 7F 01 02 u1 u2 u3 u4 u5 u6 u7 u8...

Page 8: ...may return your TR 100 to HORITA for service Please contact HORITA first either by phone or mail before returning your unit 7 SPECIFICATIONS Power Operation 9 to 14V DC approx 500 mA AC Adapter 9 volt...

Reviews: