background image

INSTRUCTION MANUAL

7

EU regulations

Conformable standards

This equipment conforms to the following standards:

Information on disposal of electrical and electronic equipment and disposal of batteries and accumulators

The crossed out wheeled bin symbol with underbar shown on the product or accompanying documents indicates the product 
requires appropriate treatment, collection and recycle for waste electrical and electronic equipment (WEEE) under the Directive 
2012/19/EU, and/or waste batteries and accumulators under the Directive 2006/66/EC in the European Union. 
The symbol might be put with one of the chemical symbols below. In this case, it satisfies the requirements of the Directive 2006/
66/EC for the object chemical. 
This product should not be disposed of as unsorted household waste.
Your correct disposal of WEEE, waste batteries and accumulators will contribute to reducing wasteful consumption of natural 
resources, and protecting human health and the environment from potential negative effects caused by hazardous substance in 
products.
Contact your supplier for information on applicable disposal methods

Authorised Representative in EU

HORIBA UK Limited
2 Dalston Gardens, Stanmore, Middx HA7 1BQ, UK

FCC Warning

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC 
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated 
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and 
used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this 
equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the inter-
ference at his own expense.

1.

Cautions on use

Safety precautions

Points of concern

Only use the product including accessories for their intended purpose.

Do not disassemble any parts not specified in this manual. This may cause malfunction. 

Do not drop the electrode. And do not apply excessive force to the sensor and converter. 

Do not scratch or apply excessive force to the sensing part and liquid junction.  

Avoid continuous use in acids or alkali sample of 0.01 mol/L or thicker. Failure to comply may cause decline in the 
performance and life period of the electrode. 

EMC:

EN61326-1
Class B, Basic electromagnetic environment

RoHS:

EN50581
9. Monitoring and control instruments

Warning:

This product is not intended for use in industrial environments. In an industrial environment, electromagnetic 
environmental effects may cause the incorrect performance of the product in which case the user may be 
required to take adequate measures.

CAUTION

Handle carefully the sharp electrode tip to not get hurt.

If calibration standard solution gets on the skin, wash off it completely. In case that the solution gets 
into the eyes, continue to flush the eyes with running water for at least 15 minutes. And after washing 
the eyes thoroughly, get medical help immediately.

Do not eat the whole, or the part around where the electrode sensor touched, of measured samples. 
Some of the sensor materials may generate environmental endocrine  disrupters.

Summary of Contents for 0030-10D

Page 1: ...charge should any mal function occur during the course of normal use if returned within the warranty period 12 months from date of purchase Return the con verter with proof of purchase date This warra...

Page 2: ...INSTRUCTION MANUAL 2 1 ISFET 70 mm 0 01 mol L ABS 1 3 33 mol L KCl 300 30 0 60 C 0 40 C ISFET 6 25 C 200 OFF Low Batt LED Meas LED 500 15 70 mm...

Page 3: ...0131 pH 0 14 0 60 C 0 40 C 0 40 C 190 mm ISFET CMC KCl 5 ABS 16 mm pH D 10 D 20 D 50 D 70 F 10 F 20 F 50 F 70 DC 6 V CR2032 2 OFF Meas LED ON Low Batt LED 1 m 0131 1 1 CR2032 2 3 33 mol L KCl 300 1 1...

Page 4: ...INSTRUCTION MANUAL 4 3 ISFET pH Note ISFET pH pH 1 pH 2 3 pH 4 pH 1 2 CR2032 2 3 a A a A 1 O 2 3 O 4 3 33 mol L KCl 300 30 O...

Page 5: ...TION MANUAL 5 4 Note ISFET 5 Note 3 33 mol L KCl 300 30 1 3 33 mol L KCl 300 10 2 ON Meas LED Note ON 1 OFF 3 pH7 4 pH Note pH pH CLR 5 pH pH 1 2 ON Meas LED Note ON 1 OFF 3 4 pH mV 0 10 mV pH pH 7 pH...

Page 6: ...INSTRUCTION MANUAL 6 6 7 4 5 Note 2 CR2032 1 OFF Meas LED 2 Note 1 2 Note Note 220 1 OFF 2 3 4 Note Low Batt LED 1 OFF 2 3 4 4 4...

Page 7: ...can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a resi...

Page 8: ...sensor cannot be repaired Before replacing the sensor or batteries turn off the power and wipe water off the electrode by patting the electrode dry with filter paper Make sure to detach the sensor be...

Page 9: ...he nut is not tightened enough water may enter the inside of the sensor and the sensor may be damaged Before measurement or calibration prepare the ISFET pH electrode as follows Connecting to pH meter...

Page 10: ...pH7 standard solution with the sensing part and liquid junction completely immersed If necessary swing the sensor gently in the solution to remove bubbles near the sensing part and liquid junc tion 4...

Page 11: ...If the electrode is very dirty and cannot be washed clean using pure water clean it as follows 1 Clean the sensing part by wiping it with cotton gauze containing cleans ing agent 2 Rinse the electrod...

Page 12: ...i cho Kisshoin Minami ku Kyoto 601 8306 Japan 0120 37 6045 9 00 12 00 13 00 17 00 For any questions regarding this product please contact your local agency or inquire from the following website http g...

Reviews: