Page 1: ...23 PANEL MOUNT INDUSTRIAL MONITOR USER MANUAL Model No HIS ML23 _ _ _ D REVISION D...

Page 2: ...tep 2 Bench test Configuration 8 Install Cable Connections 8 Install Touch Screen Driver 10 Step 3 Install into Panel 12 Video Settings 14 Setting the Timing Mode 14 Control Panel Buttons 15 On Screen...

Page 3: ...dition the socket outlet shall be installed near the equipment and shall be easily accessible DC Supplied Units only The HISML23 subject unit is to be powered by a Listed Power Supply suitable for the...

Page 4: ...in Class I Division 2 Groups A B C and D Class II Division 2 Groups F and G Class III or non hazardous locations only Device is open type and is to be installed in an enclosure suitable for the envir...

Page 5: ...ront and Side Views Bottom View 312 1 mm 12 29 7 1 mm 0 28 374 7 mm 14 75 596 9 mm 23 50 509 2 mm 20 05 286 4 mm 11 28 596 9 mm 23 50 7 1 mm 0 28 536 4 mm 21 12 53 8 mm 2 12 Design to maximum depth of...

Page 6: ...Mechanical Drawings 6 ML23D User Manual 99172C September 2021 Rear View MENU SEL 100 mm VESA Mounting Pattern M4 screws provided 16 mm maximum depth of screw...

Page 7: ...C 122 F f Remember that heat rises the temperature at the top of the cabinet will be much hotter than at the bottom if air inside the enclosure is not actively circulating Even in a sealed enclosure...

Page 8: ...m issues while configuration changes may still be easily made Install Cable Connections All monitors are shipped with a standard VGA video cable AC powered displays are also shipped with a power mains...

Page 9: ...yPort connection this can be converted for use with the DVI video port using a simple adapter If the video source has a 5 wire analog RGB video output this can be converted for use with the VGA video...

Page 10: ...ope Industrial Systems if you require a CD ROM with documentation and drivers for touch screens For a full list of downloadable drivers please check the following Internet address https www HopeIndust...

Page 11: ...locks on the cable connectors to ensure adequate strain relief HAZ LOC NOTE If this step is not performed the product will not comply with Class I II III Division 2 Hazardous Location requirements 2...

Page 12: ...the panel Allow extra space 25 4 mm 1 0 behind and on each side for air ventilation Step 3 Install into Panel Once you have completed the full bench test configuration and confirmed that all component...

Page 13: ...elow 7 Insert the unit into the front of the panel and re attach the collar NOTE Contact Hope Industrial Systems if for any reason your application does not allow for installation of the collar 8 Tigh...

Page 14: ...screen image TIP For the best picture quality set your computer graphics adapter timing mode to VESA 1920 x 1080 60 Hz Please refer to the computer graphics adapter manufacturer s manual for instructi...

Page 15: ...tically after 60 seconds This is adjustable through the OSD Time out setting in the Setup menu 2 To navigate through the main OSD menu press the left or right button 3 To select a control to adjust pr...

Page 16: ...displayed Shortcut to adjust Brightness When the OSD menu IS displayed Navigates left in the main OSD menu Decreases adjustments for the selected control Right Up When the OSD menu IS displayed Navig...

Page 17: ...e Inputs OSD Info Reset to factory defaults Source scan and Advanced Setup functions Picture Menu The Picture menu includes the Contrast Brightness Sharpness and Color functions Picture Menu Descripti...

Page 18: ...tent white red blue green Please contact our support team for further details NOTE The Auto color function is only available when using the analog VGA connector Theme mode Allows the user to select fr...

Page 19: ...the screen for warmer white and richer red Normal is the factory default setting Cold adds blue to the screen image for cooler white VGA Settings Menu The VGA Settings menu includes the Timing Auto s...

Page 20: ...position Vertical Position Moves the screen image up and down H position Horizontal Position Moves the screen image left and right Phase Adjusts the focus of the screen image Allows the user to remove...

Page 21: ...uage used in the menus and control screens Rotation allows the user to rotate the OSD by 0 90 180 or 270 A Mirrored setting is also available which is a horizontal reflection of the OSD OSD Position a...

Page 22: ...dvanced Setup submenu contains two additional settings Smart ISP flashes the video board firmware Do not activate without assistance from Hope Industrial technical support CVT Mode set to On will forc...

Page 23: ...content Vinegar or ammonia will not hurt the screen The anti reflective coatings on glass window equipped displays are physically part of the surface of the glass and resist degradation to the Milita...

Page 24: ...oltage is 9 6 to 36 6 VDC No image on the screen and control s Power Indicator light is lit solid red Monitor is not powered on Press the Power button on the monitor for 1 2 seconds to turn the monito...

Page 25: ...function may also be activated by pressing the Select SEL button outside of the OSD menu Fine tune the picture by manually adjusting the image using the settings in the OSD menu Analog signal is not a...

Page 26: ...the USB cable length exceed 5 meters USB cables have a 5 meter limitation and could cause no touch response if this is exceeded If using a Serial connection is the Serial cable plugged into the correc...

Page 27: ...s 16 7 million Brightness white 250 nits cd m2 Viewing Angle Hori Vert 178 178 Contrast Ratio typical 1000 1 static 20 000 000 1 dynamic Backlight typical LED 40 000 hour brightness half life Environm...

Page 28: ...call for details Horizontal Scan 24 82 kHz Vertical Scan 50 75 Hz Supported Video Standards 1920 x 1080 60 Hz 1680 x 1050 60 Hz 1600 x 1200 60 Hz 1600 x 900 60 Hz 1400 x 1050 60 Hz 1440 x 900 60 75 H...

Page 29: ...of Panel 46 7 mm 1 84 NOTE Design to maximum depth of 69 0 mm 62 0 mm behind front edge of panel to ensure future compatibility with later revisions and replacement units Front Bezel Outside Dimensio...

Page 30: ...ability WEEE Registration No WEE DJ1859ZX for UK only Enclosure UL 50E File No E318630 Hazardous Location AC power models UL Rated for Hazardous Locations Industrial Control Equipment for Hazardous Lo...

Page 31: ...ed we will give you a Return Material Authorization RMA number This RMA number must be conspicuously marked on the outside of the shipping box Hope Industrial Systems will not accept shipments not acc...

Page 32: ...44 0 20 7193 2618 HopeIndustrial fr Germany Phone 44 0 20 7193 2618 HopeIndustrial de Italy Phone 39 80 0740414 HopeIndustrial it Spain Phone 34 91 1438229 HopeIndustrial es EU Authorized Representati...