background image

2

GETTING TO kNOw yOUR ClEANER

A.  Cleaner main body
B.  Carry handle
C.  Dust Container
D.  Dust Container handle and latch
E.  On/Off Button
F. 

Cord Rewind Button

G. 

Filter Door

H.  Filter Door latch
I. 

Pre-Motor Filter Pack

J. 

Exhaust Filter Door

K.  Exhaust Filter
L. 

Parking slot

M.  Handle*
N.  suction Control*
O.  Telescopic Tube*
P.  Telescopic Tube Adjuster*
Q.  Carpet and Floor nozzle(

GP

)**

R.  surface selector
s.  Hose
T. 

Accessories*

U.  Pet Hair Remover Mini Turbo Nozzle*
V.  Allergen Remover Mini Turbo Nozzle*
W.  Turbo Nozzle*
X. 

Parquet Nozzle*

ASSEmblING yOUR ClEANER

Remove all components from the packaging.

1.  Connect the hose to the cleaner main body, ensuring it clips and locks into position.  

To release: simply press the two buttons on the hose end and pull. 

[2]

2.  Connect the tube upper end to the hose handle and store the accessories on the 

handle.

 [3]

3. 

Connect the tube lower end to the carpet and floor nozzle**. 

[4]

*Certain models Only

   

** Certain models only, nozzles may vary according to model

Q1.   Carpet Nozzle (

CA

)**

Q2.   Hard Floor Nozzle (

HF

)**

USING yOUR ClEANER

1.  Extract power cord and plug it into the power supply. Do not pull the cord beyond 

the red marker. 

[5]

2.  Adjust the telescopic tube to the desired height by holding the handle and moving 

the telescopic tube adjuster up or down. 

[6]

3.  select carpet care control height by pressing the pedal in the nozzle. 

[7]

 

 

Hard Floor  –  Brushes are lowered to protect the floor.

 

 

Carpet  –  Brushes are raised for the deepest clean.

4.  switch the cleaner on by pressing the On/Off Button on the cleaner main body. 

[8]

5.  Adjust the suction by sliding the suction control to the desired level. 

[9]

6.   switch off at the end of use by pressing the On/Off Button. Unplug and press the 

cord rewind button to wind the power cord back into the cleaner. 

[10]

7.  To store your cleaner adjust telescopic tube to the lowest height setting and park the 

nozzle in the park position on the cleaner main body. 

[11]

ACCESSORIES

To  obtain  the  best  performance  and  energy  efficiency

 

#1

 it is recommended that the 

correct nozzles are used for the main cleaning operations. These nozzles are indicated 
in the diagrams by the letters 

GP

HF

 or 

CA

.

A nozzle type 

GP 

can be used to clean both carpet and hard floor.

A nozzle type 

HF

 is suitable for use only on hard floor.

A nozzle of type 

CA

 is suitable for use only on carpet.

The other nozzles are accessories for specialist cleaning tasks and are recommended 
for occasional use only.

It is important to note that this vacuum cleaner is supplied with an Energy Label as re-

quired by European Regulation (EU) 665/2013.

If the label shows a red prohibition circle on the left covering the carpet symbol, then this 
indicates that the vacuum cleaner is not suitable use on carpets.

If the label shows a red prohibition circle on the right covering the hard floor symbol, then 
this indicates that the vacuum cleaner is not suitable for use on hard floors.

#1

NOTE: 

Dust pick up ability carpet, dust pick up ability hard floor, and energy efficiency 

in accord with Commission Regulations (EU) 665/2013 and (EU) 666/2013.

All accessories can be fitted to the end of the handle or the end of the telescopic tube.

3 in 1 tool*

 – Combines several functions in one, with maximum flexibility by the rotating 

body. Reach into awkward areas by rotating the body. The 3 in 1 tool can be stored neatly 

Summary of Contents for Xarion Pro

Page 1: ... USER MANUAL PRINTED IN P R C 48011352 1 Certain models only Certain models only nozzles may vary according to model U V W X E J L F C T A I N N P O T M S Q D B H G P R O M K Q1 Q2 GP CA HF ...

Page 2: ... Certain models only Certain models only nozzles may vary according to model 2 3 4 5 6 7 8 10 12 14 13 15 16 17 18 19 20 21 22 23 24 25 11 MI D 9 ...

Page 3: ...surface or for wet pick up Do not pick up hard or sharp objects matches hot ashes cigarette ends or other similar items Do not spray with or pick up flammable liquids cleaning fluids aerosols or their vapours Do not run over the power cord when using your appliance or remove the plug by pulling on the power cord Do not continue to use your appliance if it appears faulty HOOVER service To ensure th...

Page 4: ...sliding the suction control to the desired level 9 6 Switch off at the end of use by pressing the On Off Button Unplug and press the cord rewind button to wind the power cord back into the cleaner 10 7 To store your cleaner adjust telescopic tube to the lowest height setting and park the nozzle in the park position on the cleaner main body 11 Accessories To obtain the best performance and energy e...

Page 5: ...lure This may invalidate your guarantee IMPORTANT Regularly check and maintain the filters IMPORTANT Always ensure the filter pack is fully dry before use To access the Pre Motor filter NOTE Ensure the carry handle is at its down position before opening the filter door 1 Unlock the filter door by pulling the filter latch upwards Open the filter door 17 2 Remove the blue filter pack by pressing dow...

Page 6: ...zzle blocked Please refer to Removing a blockage from the system Has the cleaner overheated If so it will take approximately 30 minutes to automatically reset Important Information Hoover spares and Consumables Always replace parts with genuine Hoover spares These are available from your local Hoover dealer or direct from Hoover When ordering parts always quote your model number Hoover Service Sho...

Reviews: