Hoover SteamVac F5807 Owner'S Manual Download Page 2

2

WARNING:

To reduce the risk of fire, electric
shock, or injury:

When using an electrical appliance, always follow

basic precaution, including the following:

READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE

Important Safeguards!

Questions or Concerns?

The Hoover Company wants to quickly resolve any
concerns about your cleaner or questions regard-
ing its use.  Look on the list provided with the
product for your local

 Hoover Factory Service

Center 

or in the Yellow Pages under “Vacuum

Cleaners - Household” for the nearest

 Authorized

Hoover Warranty Service Dealer 

(Depot) or call:

1-800-944-9200 

for an automated referral

of authorized service outlet locations (U.S. only) or

1-330-499-9499 (U.S.) or 1-800-263-6376

(Canada) to speak with a Hoover representative.

PLEASE DO NOT RETURN THIS PRODUCT
TO THE STORE OR SEND IT TO NORTH
CANTON FOR SERVICE.

Unpacking

L

C D

E

F

H

G

I

A

• Use indoors only.
• Use only on surfaces moistened by the cleaning process or small

spills.  Do not immerse product.

• Connect to a properly grounded outlet only.  See “Grounding Instruc-

tions”.

• Do not clean over floor electrical outlets.
• Do not use without tanks in place.
• Use extra care when cleaning on stairs.  Do not place carpet cleaning

machine on stairs.

• Use deep cleaner only for its intended use as described in

the instructions.  Use only attachments recommended by The Hoover
Company; others may cause hazards.

• The use of an extension cord is not recommended.  If an extension

cord is absolutely necessary, use at least a 16 gauge 3-wire cord which
has a 3-prong grounding type plug and a 3-pole receptacle that accepts
the machine plug.

• Unplug deep cleaner when not in use.  Turn off all controls

before unplugging.

• Always disconnect cord from electrical outlet before servicing the

deep cleaner.

• Do not unplug by pulling on cord.  To unplug, grasp the plug, not the

cord.  Never handle plug or appliance with wet hands.

• Do not pull or carry by cord, use cord as a handle, close door on cord or

pull cord around sharp edges or corners.  Do not run appliance over
cord.  Keep cord away from heated surfaces.

• Do not use with damaged cord or plug.  If appliance is not working as it

should, has been dropped, damaged, left outdoors, or dropped into
water, take it to a Hoover Factory Service Center or Authorized Hoover
Warranty Service Dealer.

• Close supervision is necessary when any appliance is used by or

near children.  Do not allow deep cleaner to be used as a toy or to run
unattended at any time.

• Do not point stair/upholstery tool toward people or pets.
• To assist in reducing drying time, be certain the area is well ventilated

when using detergents and other cleaners with this machine.

• Keep detergents and other cleaners out of children’s reach.
• Do not use to pick up flammable or combustible liquids such as gaso-

line or use in areas where they may be present.

• Do not pick up chlorine bleach, drain cleaner, gasoline or any other

toxic material with this appliance.

• Do not pick up anything that is burning or smoking, such as cigarettes,

matches, or hot ashes.

• Avoid picking up hard, sharp objects with the deep cleaner.

They may damage the machine.

• Keep hair, loose clothing, fingers, feet and all parts of body away

from openings and moving parts.

• Do not put any object into openings.  Do not use with any opening

blocked; keep free of dust, lint, hair, and anything that may reduce
air flow.

• To help prevent matting and resoiling, avoid contact with carpets until

they are dry.  Keep children and pets away from carpets until they are
completely dry.

• Store in a dry place.  Do not expose machine to freezing temperatures.

J

Unpack deep cleaner from the carton and
identify the parts shown.  Remove and dispose
of the  packing.

B

B

A. Deep cleaner
B. Upper handle    OR

Upper handle with hose/nozzle rack*

C. Bolts (2)
D. Nuts (3 - one extra included)
E. Carpet/Upholstery Detergent
F. Bare Floor Cleaner*
G. PreCleaner*
H. Bare floor attachment*
I.

Hose*

J.  Stair/upholstery nozzle*
K. Lower hose hook and screw*
L.  Nozzle clean-out tool*

*Included with some models.

SteamVac™ Deep Cleaner cleans carpet
fibers by applying hot tap water and
cleaning solution.

Save these instructions!

Safeguards - Unpacking - Assembly

K

J

Summary of Contents for SteamVac F5807

Page 1: ...ug illustrated in sketch A A GROUNDING PIN B This appliance must be grounded If it should malfunction or breakdown grounding provides a path of least resistance for electrical current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and grounding plug A The plug must be plugged into an appropriate outlet B that is properly installe...

Page 2: ...round sharp edges or corners Do not run appliance over cord Keep cord away from heated surfaces Do not use with damaged cord or plug If appliance is not working as it should has been dropped damaged left outdoors or dropped into water take it to a Hoover Factory Service Center or Authorized Hoover Warranty Service Dealer Close supervision is necessary when any appliance is used by or near children...

Page 3: ...ueeze trigger on upper handle to snap trigger rod in place Fig 6 6 SQUEEZE TRIGGER 7 Replace clean solution tank upper tank by positioning bottom first Press on tank handle to snap top of tank into place Fig 7 TANK HANDLE 1 2 B 3 With cord hook to back of deep cleaner push upper handle down onto lower handle Fig 3 CORD HOOK Remove nozzle stored on upper handle by gently pushing nozzle downward whi...

Page 4: ...rd tight Fig 8 HOSE HOLDER PROJECTIONS HOLES EXTENSION HOOK While aligning arrows Fig 14 place extension into bottom of converter opening then push converter firmly against deep cleaner until it snaps into place Secure solution hose to converter as shown To remove first pull top of converter off extension then pull off bottom To store hose on rack begin by placing nozzle connector end of hose stra...

Page 5: ...le 9 Clean solution tank cap measuring cup 10 Clean solution tank holds cleaning solution 11 Recovery tank lid 12 Recovery tank holds dirty solution 13 Recovery tank front panel 14 Hood 15 Nozzle 16 Upholstery and stair cleaning connection push door open to connect stair upholstery nozzle solution tube 17 Recovery tank latches one on each side of tank 18 ON OFF pedal 19 Handle release pedal step o...

Page 6: ...p cleaner off and empty recovery tank before continuing use Handle release pedal Automatic shut off FLOAT DISK Clean solution tank upper tank The clean solution tank holds the cleaning solution that is to be dispersed onto the surface to be cleaned The deep cleaner may also be lifted by placing a hand under the upper clean solution tank handle as shown The tanks How to fill TANK HANDLE Carry tank ...

Page 7: ...onnect from electrical outlet TANK HANDLE To prevent possible leaking remove clean solution tank by pressing down on tank handle and pulling forward set tank aside do not set tank on furniture FILL LINE If rubber ring on cap has displaced replace it with uneven side against cap ledge as shown Pour detergent into tank Fill tank to fill line 1 gallon with hot tap water To assure proper performance u...

Page 8: ...y not be necessary if only high traffic areas are to be cleaned For furniture too heavy to move place aluminum foil or wax paper under legs This will prevent wood finishes from staining carpet Pin up furniture skirts and draperies e Pretreat spots and heavy traffic areas with HOOVER PreCleaner Test PreCleaner for colorfast ness by first spraying it on a hidden area wait ten minutes and blot with w...

Page 9: ...ep cleaner back to ward you without squeezing trigger dry stroke To avoid walking on damp carpet start at the end of the room farthest from the door or path to sink where tanks will be emptied and filled Step on handle release pedal and lower handle to operating position turn deep cleaner ON Dry hands and plug cord into a properly grounded outlet Do not clean over floor electrical outlets Cleaning...

Page 10: ...lace Return deep cleaner to upright position Lower handle and replace recovery tank Press down to ensure that it is properly seated in place Rotate latches one on each side of tank inward to lock tank in place Raise handle to upright position To clean floor Read Before you begin cleaning instructions on page 8 Do not use the SteamVac deep cleaner on hardwood floors Fill clean solution tank accordi...

Page 11: ...m storage rack Unlatch back part of recovery tank lid and remove lid Before connecting tube to cleaner make sure black tabs are extended by pulling tan collar toward tube Open door on hood labeled Stair Upholstery Cleaning Connection Press round solution tube connector onto round projection inside door Press connector collar down firmly to ensure that it is fully connected TABS FRONT The tank lid ...

Page 12: ...escribed above End with more dry strokes to aid in faster drying of carpet Overlap strokes by one half inch to help prevent streaking To avoid saturating carpet do not use more than 4 wet strokes over any one area Always end with dry strokes After using stair upholstery nozzle Disconnect deep cleaner from electrical outlet Follow the instructions for After cleaning on page 9 Drain suction hose by ...

Page 13: ...ocess Make crisscrossing strokes to the original pattern overlap each pass Make no more than 2 passes with the solution over any one area to prevent overwetting and damage to fabric Storage Before storing Empty solution tank and rinse thoroughly with clean water Replace empty solution tank and turn deep cleaner ON Squeeze trigger and push deep cleaner forward and back several times to expel any so...

Page 14: ...ccording to instructions for surface being cleaned pages 6 7 Recovery tank lid not on correctly Make sure lid is firmly in place page 8 Stair upholstery solution tube not securely fastened Make sure tube is securely fastened at connection of hood Possible cause Possible solution Problem Solution tube on stair upyholstery nozzle won t connect Possible cause Possible solution Connector collar pushed...

Reviews: