Hoover SteamVac F5807 Owner'S Manual Download Page 12

12

Cleaning carpeted stairs

Read “Before you begin cleaning” instructions on page 8.

Attach hose and solution tube as instructed on page 11.

Fill clean solution tank according to instructions on pages 6 and
7.  Use 5 ounces of HOOVER Carpet/Upholstery Detergent.

Hose length may require that machine be placed at the top of
the stairs to clean upper half of stairway and at bottom of stairs
to clean lower half.

To prevent machine from falling, use extra caution when
cleaning on stairs. 

 

Do not place deep cleaner on stairs.

Do not point stair/upholstery nozzle at people or pets.

Dry hands and plug deep cleaner into a 

properly grounded

outlet.

Turn deep cleaner ON.

Pre-spray the carpeted stair by holding the nozzle about one
inch above the carpet and push the wand forward while
pressing the solution trigger (equals one wet stroke).

Position nozzle against the riser and slightly press nozzle into
carpet pile.  Press the solution trigger and pull the nozzle

slowly

 over the carpet (second wet stroke).

Release the trigger, lift nozzle, and position it against riser.
Pull nozzle 

slowly 

over carpet without pressing trigger (dry

stroke).

It is best to alternate wet and dry strokes as described above.
End with more dry strokes to aid in faster drying of carpet.

Overlap strokes by one-half inch to help prevent streaking.

To avoid saturating carpet, do not use more than 4 wet
strokes over any one area.   Always end with dry strokes.

After using stair/upholstery nozzle

Disconnect deep cleaner from electrical outlet.

Follow the instructions for “After cleaning” on page 9.

Drain suction hose by turning deep cleaner on and holding
nozzle up for several minutes.  

Do not press trigger.

Disconnect cleaner from electrical outlet.

Replace recovery tank front panel. 

 

Slide panel down until it

snaps firmly in place.

Snap clip back into positon making sure solution hose is not
pinched and moves freely.

CONVERTER

CONVERTER
CLIP

SOLUTION
HOSE

Occasionally, debris may become lodged inside of the hose at
the converter end.

To clean-out the hose, lift bottom of converter clip with a screw
driver and remove clip.  Remove debris as shown.

Drain solution tube by placing round end in sink, and raising
nozzle above your head.  Press the trigger.

Disconnect hose and solution tube from deep cleaner.

If additional cleaning is necessary, wait until the carpet is
completely dry before using the nozzle again.

When finished cleaning, follow “After cleaning” instructions on
page 9 and “After using stair/upholstery nozzle” instructions on
page 12.

Stair/upholstery  nozzle - Cleaning carpeted stairs

Summary of Contents for SteamVac F5807

Page 1: ...ug illustrated in sketch A A GROUNDING PIN B This appliance must be grounded If it should malfunction or breakdown grounding provides a path of least resistance for electrical current to reduce the risk of electric shock This appliance is equipped with a cord having an equipment grounding conductor and grounding plug A The plug must be plugged into an appropriate outlet B that is properly installe...

Page 2: ...round sharp edges or corners Do not run appliance over cord Keep cord away from heated surfaces Do not use with damaged cord or plug If appliance is not working as it should has been dropped damaged left outdoors or dropped into water take it to a Hoover Factory Service Center or Authorized Hoover Warranty Service Dealer Close supervision is necessary when any appliance is used by or near children...

Page 3: ...ueeze trigger on upper handle to snap trigger rod in place Fig 6 6 SQUEEZE TRIGGER 7 Replace clean solution tank upper tank by positioning bottom first Press on tank handle to snap top of tank into place Fig 7 TANK HANDLE 1 2 B 3 With cord hook to back of deep cleaner push upper handle down onto lower handle Fig 3 CORD HOOK Remove nozzle stored on upper handle by gently pushing nozzle downward whi...

Page 4: ...rd tight Fig 8 HOSE HOLDER PROJECTIONS HOLES EXTENSION HOOK While aligning arrows Fig 14 place extension into bottom of converter opening then push converter firmly against deep cleaner until it snaps into place Secure solution hose to converter as shown To remove first pull top of converter off extension then pull off bottom To store hose on rack begin by placing nozzle connector end of hose stra...

Page 5: ...le 9 Clean solution tank cap measuring cup 10 Clean solution tank holds cleaning solution 11 Recovery tank lid 12 Recovery tank holds dirty solution 13 Recovery tank front panel 14 Hood 15 Nozzle 16 Upholstery and stair cleaning connection push door open to connect stair upholstery nozzle solution tube 17 Recovery tank latches one on each side of tank 18 ON OFF pedal 19 Handle release pedal step o...

Page 6: ...p cleaner off and empty recovery tank before continuing use Handle release pedal Automatic shut off FLOAT DISK Clean solution tank upper tank The clean solution tank holds the cleaning solution that is to be dispersed onto the surface to be cleaned The deep cleaner may also be lifted by placing a hand under the upper clean solution tank handle as shown The tanks How to fill TANK HANDLE Carry tank ...

Page 7: ...onnect from electrical outlet TANK HANDLE To prevent possible leaking remove clean solution tank by pressing down on tank handle and pulling forward set tank aside do not set tank on furniture FILL LINE If rubber ring on cap has displaced replace it with uneven side against cap ledge as shown Pour detergent into tank Fill tank to fill line 1 gallon with hot tap water To assure proper performance u...

Page 8: ...y not be necessary if only high traffic areas are to be cleaned For furniture too heavy to move place aluminum foil or wax paper under legs This will prevent wood finishes from staining carpet Pin up furniture skirts and draperies e Pretreat spots and heavy traffic areas with HOOVER PreCleaner Test PreCleaner for colorfast ness by first spraying it on a hidden area wait ten minutes and blot with w...

Page 9: ...ep cleaner back to ward you without squeezing trigger dry stroke To avoid walking on damp carpet start at the end of the room farthest from the door or path to sink where tanks will be emptied and filled Step on handle release pedal and lower handle to operating position turn deep cleaner ON Dry hands and plug cord into a properly grounded outlet Do not clean over floor electrical outlets Cleaning...

Page 10: ...lace Return deep cleaner to upright position Lower handle and replace recovery tank Press down to ensure that it is properly seated in place Rotate latches one on each side of tank inward to lock tank in place Raise handle to upright position To clean floor Read Before you begin cleaning instructions on page 8 Do not use the SteamVac deep cleaner on hardwood floors Fill clean solution tank accordi...

Page 11: ...m storage rack Unlatch back part of recovery tank lid and remove lid Before connecting tube to cleaner make sure black tabs are extended by pulling tan collar toward tube Open door on hood labeled Stair Upholstery Cleaning Connection Press round solution tube connector onto round projection inside door Press connector collar down firmly to ensure that it is fully connected TABS FRONT The tank lid ...

Page 12: ...escribed above End with more dry strokes to aid in faster drying of carpet Overlap strokes by one half inch to help prevent streaking To avoid saturating carpet do not use more than 4 wet strokes over any one area Always end with dry strokes After using stair upholstery nozzle Disconnect deep cleaner from electrical outlet Follow the instructions for After cleaning on page 9 Drain suction hose by ...

Page 13: ...ocess Make crisscrossing strokes to the original pattern overlap each pass Make no more than 2 passes with the solution over any one area to prevent overwetting and damage to fabric Storage Before storing Empty solution tank and rinse thoroughly with clean water Replace empty solution tank and turn deep cleaner ON Squeeze trigger and push deep cleaner forward and back several times to expel any so...

Page 14: ...ccording to instructions for surface being cleaned pages 6 7 Recovery tank lid not on correctly Make sure lid is firmly in place page 8 Stair upholstery solution tube not securely fastened Make sure tube is securely fastened at connection of hood Possible cause Possible solution Problem Solution tube on stair upyholstery nozzle won t connect Possible cause Possible solution Connector collar pushed...

Reviews: