Hoover PRO STAIR User Instructions Download Page 2

- 2 -

IMPORTANT SAFETY REMINDERS

User’s manual - This cleaner should only be used 
for its intended purpose as described in these 
instructions.  Ensure that these are fully understood 
before operating this appliance. 

Only use attachments recommended or supplied by 
Hoover.

When using cleaning tools ensure that the cleaner is 
kept in the upright (parked) position.  This will avoid 

possible damage to the carpet or floor covering.

When cleaning stairs 

DO NOT

 position the cleaner 

above you.

Safety with Children, Elderly or the Infirm: Do not let 

children play with the appliance or its controls.  Please 
supervise the use of the appliance by older children, 

the elderly and the infirm.

STATIC ELECTRICITY.  Some carpets can cause a 
small build up of static electricity. 
Any static discharge is not hazardous to health.

DO NOT

 

use your cleaner out of doors or on any 

wet surface or for wet pick up. 

Keep hands, feet, loose clothing and hair away from 
rotating brushes.

DO NOT

 pick up hard or sharp objects, matches, 

cigarette ends or other similar items.

DO NOT

 

pick up flammable liquids such as cleaning 

fluids, petrol etc. or their vapours. 

Aerosol sprays may be flammable. 

DO NOT

 spray 

near cleaner.

SUPPLY CORD. 

 

DO NOT

 

run over the supply 

cord when using your cleaner or remove the plug by 
pulling on the supply cord.

FAULTS.  

DO NOT

 continue to use your cleaner if 

it appears to be faulty. If the supply cord is damaged 

stop using the cleaner IMMEDIATELY.

The supply cord must be replaced by an authorised 
Hoover service engineer to avoid a safety hazard.

AFTER USE.  Switch the cleaner off and remove the 
plug from the electricity supply.
Always switch off and remove the plug before 
cleaning the appliance or attempting any maintenance 
task.
HOOVER SERVICE.   To ensure the continued 

safe and efficient operation of this appliance we 

recommend that any servicing or repairs are only 
carried out by an authorised Hoover service engineer.

Genuine Hoover Spares and Consumables

Always replace parts with Genuine Hoover spares and consumables.

 

HOOVER SERVICE 08705 400 600
HOOVER SPARES  01204 556 111

Congratulations on the purchase of your new 
Hoover Pro Stair.

This highly advanced machine makes cleaning 

easier and more efficient.

You’ll find it kinder to your carpets - and to 

you!

Please take the time to read this manual 

carefully.

You’ll be ready to make the most of the special 
features only the new Hoover Pro Stair can 
offer!

WARNING!

ELECTRICITY CAN BE 

EXTREMELY DANGEROUS

This appliance is double insulated and must 
not be earthed.
The plug is fitted with a 13 amp fuse.
IMPORTANT:  The wires in the mains lead 
are coloured in accordance with the following 
code: 

Blue - NEUTRAL
Brown - LIVE

- 2 -

PRO STAIR

0565-5296.indd   2

29/11/2007   16:23:37

Summary of Contents for PRO STAIR

Page 1: ...USER INSTRUCTIONS GENERATION FUTURE 0565 5296 indd 1 29 11 2007 16 23 36 ...

Page 2: ...e the plug by pulling on the supply cord FAULTS DO NOT continue to use your cleaner if it appears to be faulty If the supply cord is damaged stop using the cleaner IMMEDIATELY The supply cord must be replaced by an authorised Hoover service engineer to avoid a safety hazard AFTER USE Switch the cleaner off and remove the plug from the electricity supply Always switch off and remove the plug before...

Page 3: ...ing contact your retailer or call the Hoover helpline on 08705 400 600 Dusting brush Grooming nozzle Hose hook Pro Stair Brush Cord storage swivel hook Supply cord Flexible hose Hose supports Exhaust filter cover behind Pro Stair Lock Carrying handle Hose retainer Long Crevice Tool Pro Stair Telescopic tube 3 Cleaner lock release Important Note The Long Crevice Tool is located inside the Pro Stair...

Page 4: ... nozzle height will not change until the handle is released Try various settings until you get the best results for each of your carpets Ensure that the cleaner is in an upright parked position Slide selector to the position best suited to depth of carpet pile Using this cleaner for carpets with pile greater than 30mm is not recommended Unlock the cleaner by pressing down on pedal with foot For fl...

Page 5: ...flexible hose Combine accessories depending on use Always attach the hose retainer to the hose hook when using the cleaning tools Unhook after use To use your Pro Stair Brush as a Crevice tool rotate the tool to the Open position as shown Return to the closed position after use When using the Pro Stair Brush keep the base of the nozzle flat to the carpet When cleaning treads risers use the crevice...

Page 6: ...ansparent shroud including the RED vortex finder Empty the dust container of dirt and debris IMPORTANT DO NOT FILL ABOVE THE INDICATED MAX LEVEL MARK SHOWN ON THE CASSETTE Repeat all steps in reverse to refit the dust container on the product Make sure that the RED and BLUE components are refitted IMPORTANT For optimum cleaning performance always keep your filters clean Hoover recommends to wash P...

Page 7: ... the exhaust cover and filter IMPORTANT For optimum cleaning performance always keep your filters clean Separate the GREY foam filter from the BLUE filter pack using the tab provided Wash the GREY foam filter thoroughly Gently tap to release excess dust Wash the filter with the BLUE housing from the inside DO NOT USE HOT WATER OR DETERGENTS Remove excess water by shaking and leave to dry for 24 ho...

Page 8: ...e Control selector Ensure the raised face T is towards the front of the cleaner 4 5 3 1 2 IMPORTANT Switch cleaner off and remove plug from electricity supply before checking the brushes or removing hood 1 2 CHANGING BELT OR BRUSHES This cleaner is unlikely to become blocked except by over filling of the dust container or accidentally picking up large solid objects Clearing a blockage is simple If...

Page 9: ...t UK national authority for the safety of domestic electical appliances ensure that European Safety Standards are met and are maintained throughout the production life of an appliance All appliances which pass these tests are permitted to carry this BEAB mark of safety BEAB Appproved Use only HOOVER spares 9 GUARANTEE STATEMENT The guarantee conditions for the appliance are as defined by our repre...

Page 10: ... on page 8 8 Has the cleaner overheated If so it will take about 30 minutes to reset itself If there is any doubt call the Hoover Service Office for advice They may be able to assist you over the telephone A service charge will be made if the cleaner is examined and found to be in working order has not been assembled in accordance with these instructions or has been used incorrectly WARNING A ther...

Page 11: ...0565 5296 indd 11 29 11 2007 16 23 43 ...

Page 12: ...GENERATION FUTURE Printed in P R C 0565 5296 0565 5296 indd 12 29 11 2007 16 23 44 ...

Reviews: