3 - 1 8

3 - 1 9

Agitator brush roll
replacement

When to replace

Disconnect cleaner from electrical
outlet.

When agitator brush roll brushes are
w o rn, the brush roll should be re p l a c e d .

To check condition of brushes, move
edge of a card across bottom plate while
t u rning brush roll.  To maintain cleaning
e ffectiveness, replace brush roll if bru s h-
es do not touch card .

What to buy

When purchasing a new agitator bru s h
roll, ask for HOOVER 

p a rt  n o .4 8 4 1 4 -

0 7 1 .

How to replace

Disconnect cleaner from electrical
outlet.

1.  Remove hood, duct cover, belt and
b rush roll as shown in Figs. 3-9 to 
3 - 1 4 .

2.  Discard old brush ro l l .

3.  Replace new brush roll and belt as
shown in Figs. 3-15 to 3-17. 

2. Push old bulb into socket and twist to
remove.  Push new bulb into socket and
twist into place.
3. Replace hood.

Headlight re p l a c e-
m e n t

The headlight, located on top of the
power nozzle, operates when the clean-
er is turned on.  Use only HOOVER

part no. 27317-307

, which is a fused

bulb, when replacing the headlight. 

How to replace

Disconnect cleaner from electrical
outlet and disconnect power nozzle
from extension wands.

1. Remove the hood as shown in Figs.
3-9 and 3-10.

Position hood on top of nozzle base.  

Tu rn nozzle over. Replace 2 short scre w s
at the back of nozzle and 2 long scre w s
at the fro n t .

Replace brush roll cover over agitator
b rush roll.  Replace 3 short scre w s .

Lift up end of agitator brush roll.  Remove
old belt from agitator pulley (E) and
replace with new belt.  Lettering on belt
must be visible.

Stretch belt back and attach to motor
pulley.

Hold opposite end of agitator brush ro l l
in place.  Push belt end forw a rd, ro t a t i n g
end plate (F) until it slides into place.
Tu rn agitator, making sure it rotates fre e l y.

10

3 - 1 4

3 - 1 5

3 - 1 6

3 - 1 7

E

F

C

Thermal protector

An internal thermal protector has been
used in your cleaner to prevent over-
heating if a large item or clog gets
caught in the nozzle or at the opening of
the bag. 

When the blockage is not removed,
the thermal protector will trip and
cleaner will stop running.

If this happens, turn cleaner OFF and

disconnect cleaner from electrical
outlet.

Then disconnect nozzle and

remove obstruction. Within 15 minutes
the thermal protector will cool and auto-
matically reset and cleaning may
resume.  
If cleaner does not operate, allow addi-
tional time for thermal protector to reset

.

Summary of Contents for Commercial WindTunnel

Page 1: ...Hoover WindTunnel Canister Cleaner with Powered Hand Tool Owner s Manual English pp 1 14 Español pàg 15 22 Français p 23 30 Review this manual before operating cleaner TM www hoover com ...

Page 2: ...ning or smoking such as cigarettes matches or hot ashes Do not use to pick up flammable or combustible liquids such as gasoline or fine wood sandings or use in areas where they may be present The hose contains electrical wires Do not use if damaged cut or punctured Avoid picking up hard sharp objects with the cleaner They may damage the cleaner and the bag Always turn off this appliance before con...

Page 3: ...ose With hose toward front of cleaner push hose connector into opening in bag lid When hose is attached properly hose cord plug will reach to receptacle on cleaner Insert plug as deeply into the recepta cle as possible Latch A will automati cally fasten Cleaner will not operate unless plug is inserted into receptacle To disconnect hose first remove hose cord plug from receptacle while pulling out ...

Page 4: ...grip 11 Receptacle connect power nozzle cord underneath hand grip 12 Dusting brush 13 Crevice tool 14 Hard floor tool 15 Furniture nozzle 16 Powered hand tool stores in tool lid 17 Power ON light glows when cleaner can be controlled at the hand grip 18 Suction regulator close for maximum suction open if power nozzle is difficult to push or light weight rugs or draperies are being cleaned 1 9 L a r...

Page 5: ...ockage in the nozzle hose tools or at the bag opening remove the blockage On some models two switches are used to turn the cleaner on for opera tion Press remote control switch C on hand grip to the OFF position before plugging cord into electrical outlet Plug cord into an electrical outlet and step on ON OFF pedal The POWER ON light will glow indicating that the cleaner can then be controlled at ...

Page 6: ...to push slide the control toward back to reduce the pow e r This will help p r event damage to the belt Edge cleaning Special edge groomers are provided on both sides of the nozzle to remove dirt in carpet near baseboards and furniture Guide side of nozzle parallel to edge of carpet or furniture as shown Hard surface floor cleaning The power nozzle can be used for cleaning hard surface floors such...

Page 7: ...ool into wand and snap into position To disconnect press down on the center of spring latch and remove tool 7 How to connect To use the cleaner with tools disconnect the power nozzle from the hand grip Tools may be attached directly to the hand grip With the latch in the unlock position insert tool or wand if extra length is needed then push latch to the lock position to secure To remove the tool ...

Page 8: ... Filter bag When to replace Check the bag when the CHECK BAG indicator shows red When bag is filled with dirt the cleaner will not operate effi ciently Discard used bag CAUTION Very fine materials such as face powder cornstarch fireplace ashes or fireplace soot may seal the paper bag and may cause it to burst even though it is only partially full of dirt When the cleaner is used to remove material...

Page 9: ...rectly and may create stress which could damage your power nozzle Use only a genuine HOOVER Belt part no 40201180 when a belt replacement is necessary When to replace The belt should be checked from time to time to be sure it is in good condition To check remove the hood see following section Replace the belt if it is stretched cut or broken 3 7 Continued Return nozzle to original position and lif...

Page 10: ...ct power nozzle from extension wands 1 Remove the hood as shown in Figs 3 9 and 3 10 Position hood on top of nozzle base Turn nozzle over Replace 2 short screws at the back of nozzle and 2 long screws at the front Replace brush roll cover over agitator brush roll Replace 3 short screws Lift up end of agitator brush roll Remove old belt from agitator pulley E and replace with new belt Lettering on ...

Page 11: ...nt When agitator brush roll brushes are worn the brush roll should be replaced Ask for HOOVER part no 48414 088 How to replace Disconnect cleaner from electrical outlet 1 Remove tool from hose and turn it so bottom faces up Press the latches on either side of tool and remove bottom plate A 2 Unscrew the two Philips screws and remove belt guard B 3 Remove agitator including end plates C and discard...

Page 12: ...bear ings that contain sufficient lubrication for the life of the motor The addition of lubricant could cause damage Therefore do not add lubricant to either motor bearing The agitator brush roll is equipped with two ball bearings that should be lubri cated periodically by a Hoover Factory Service Center or an authorized Hoover Warranty Service Dealer Depot Powered hand tool Belt replacement Inspe...

Page 13: ...ushes Possible cause Possible solution Bag full Replace paper bag Blockage in nozzle connector hose or wands Remove blockage Secondary filter dirty Clean filter Bag not opening Open bag by pulling folds Power set too low suction regulator open Increase power setting close suction regulator Hose not properly connected to cleaner Ensure hose is properly connected 4 If you have a problem If a minor p...

Page 14: ...the appliance to one of the following authorized warranty ser vice outlets Proof of purchase will be required before service is rendered 1 Hoover Factory Service Centers 2 Hoover Authorized Warranty Service Dealers Depots For an automated referral of autho rized service outlets in the U S A phone 1 800 944 9200 OR visit The Hoover Company online at www hoover com This warranty does not cover pick ...