PARTICULAR RECOMMENDATIONS

FOR THE OPERATOR

-

Do not operate the machine without having become fully
familiar with the contents of this manual and without having
acquired a comprehensive knowledge of the specific
techniques and machine controls.

-

Check that the area in which the machine is to be installed is
compatible with the dimensions of the machine itself before
installing this latter.

-

Only use lifting and handling means that are suited to the
weight of the machine when this must be installed or removed
either completely or in part.

-

Never allow unauthorized or unqualified personnel to start,
adjust, operate or repair the machine. Always refer to this
manual for the necessary operations.

-

The mechanical parts and electrical/electronic components
situated inside the machine are protected by entirely closed
panels.

-

Always ensure that the main switch has been set to the
“OFF” position
 before cleaning and/or servicing the machine.
This will disconnect the power source during the operator’s
intervention.

-

The electrical powering system must be equipped with an
automatic release system prior to the main machine switch
and with a suitable grounding system that complies with all
the requisites established by industrial provisions for the
prevention of accidents.

-

Always disconnect the power source if work must be carried
out on the main switch or in its vicinity.

-

All inspections and maintenance operations requiring removal
of the safety guards are carried out under the complete
responsibility of the users.
These operations should therefore only be carried out by
specialized and authorized technical personnel.

-

Make sure that none of the accident preventing safety
devices (barriers, guards, casings, microswitches, etc.) have
been tampered with and that they are all perfectly functional
before operating. These devices should be repaired if this is
not the case.

-

Never remove the safety devices.

-

To prevent personal risks, only use power tools that are
correctly connected to the grounding tap and that conform to
the national safety regulations.

-

Never ever tamper with the electrical system or with any other
mechanism.

-

Never ever use the hands  or unsuitable instruments to
locate leaks from pipes. Air, fluids under pressure or irritants
could cause serious damage to both persons and/or property.

-

Never use the hands instead of adequate tools when operating
the machine.

-

Never use the hands or other objects to stop moving parts.

- PAY THE UTMOST ATTENTION TO THE DATA PLATES

AFFIXED TO THE MACHINE WHENEVER WORKING ON
THIS OR IN THEIR NEAR VICINITY
.

-

The user is obliged to keep all the data plates and stickers in
a legible condition.

-

Never climb on to the door or on to the top of the machine.

-

It is essential for the user to replace all data plates and
stickers that may have deteriorated for any reason or that are
not clearly visible, ordering new ones from the Spares
Service of  HOONVED.

-

Contact the person in charge of maintenance in the event of
malfunctions or damage to the machine components without
proceeding with further repairs.

-

It is absolutely forbidden for anyone to use the machine for
purposes other than those explicitly established and
documented. The machine must always be used in the ways,
times and places dictated by common sense and the laws in
force in each country, even when there are no specific
provisions to govern the sector in the particular country of
use.

-

 HOONVED declines all responsibility for accidents or
damage to either persons or property as may arise
following failure to comply with either the relative safety
provisions or the instructions herein
.

-

These instructions, together with the provisions
governing machine installation and electrical
connections form an integral part of the Accident
Preventing Industrial regulations in force in each
individual country
.

-

THESE SAFETY PROVISIONS INTEGRATE AND DO NOT
SUBSTITUTE THE SAFETY PROVISIONS LOCALLY IN
FORCE
.

-

NEVER ever make hurried or inaccurate repairs that
could jeopardize the correct operation of the machine
.

-

ALWAYS ASK FOR HELP FROM SPECIALIZED
PERSONNEL IN CASE OF DOUBT
.

-

ANY TAMPERING BY THE USER RELIEVES THE
MANUFACTURER FROM ALL LIABILITY, THE USER
BEING IN THIS CASE SOLELY RESPONSIBLE TOWARDS
THE COMPETENT ACCIDENT PREVENTION
AUTHORITIES.

ENGLISH

Summary of Contents for 53 BT

Page 1: ...Instructions for user Ed 05 2002 60 BT R 53 BT ...

Page 2: ...progettazione Specifiche e principi tecnici Safety of machinery Basic concept general principles for design Technical principles and specifications in base a quanto prescritto dalle Direttive selon ce qui est prevu par les Directives on the basis of what is foreseen by the Directives 73 23 CEE 93 68 CEE LVD 89 336 CEE 92 31 CEE EMC Decliniamo ogni responsabilità per sinistri a persone o a cose der...

Page 3: ...SHWASHING MACHINE The illustrations concerning these instructions are on the inside of the back cover Mod 60 BT Realizzato da HOONVED Venegono Superiore VA Tel 0331 856111 Fax 0331 865223 Cod 35402 Ed 05 2002 53 BT ...

Page 4: ...ghly familiar with the contents of thi manual before installing setting up adjusting and servicing diswasher machine Mod 53 60 BT Only contact an authorized technical center or HOONVED in the event of breakdowns or faulty machine operation ...

Page 5: ...5 53 60 BT INDEX Important pag 4 Overall dimensions pag 6 Technical data pag 6 Decription of the controls pag 7 ENGLISH Page 8 ...

Page 6: ...3 BT 200 W 450 x 450 mm 47 kg 58 kg Relative humidity Operating and storage temperature Wash temperature Rinse temperature Water inlet max temperature Noise level 60 BT 5 40 C 20 90 50 60 C 80 90 C 50 C 70 dB A 53 BT 16 5 l 10 5 l 2 4 barØ 3 4 G 3 5 l 97 157 s Ø 31 mm Water cons per cycle Tank capacity Water supply Cycle length Boiler capacity Drain pipe fitting 53 BT 30 400V3N 50Hz 6550 W 6000 W ...

Page 7: ...dy C This comes on when the tank water reaches the preset level of temperature Indicator light machine running D When on this indicates that the cycle is in progress Start switch E When pressed this activates the normal washing cycle The light 5 goes out once the cycle has terminated Drain button N Draining condition line off on machines with drain pump only Press the button to manually drain the ...

Page 8: ...to the national safety regulations Neverevertamperwiththeelectricalsystemorwithanyother mechanism Never ever use the hands or unsuitable instruments to locate leaks from pipes Air fluids under pressure or irritants couldcauseseriousdamagetobothpersonsand orproperty Neverusethehandsinsteadofadequatetoolswhenoperating the machine Never use the hands or other objects to stop moving parts PAY THE UTMO...

Page 9: ...sed by transport Now check whether there has been any damage to the structure crushing or breakages If damage or imperfections are discovered 1 Immediately notify the haulage contractor both by phone and in writing by registered letter with return receipt attached 2 Informthemanufacturerbyregisteredletter withreturn receipt attached IMPORTANT Notification of damage or faults must be immediate in a...

Page 10: ...y and closing the door until the tube has completely filled 3 2 a Adjusting the dose Fig 8 Start the machine as described in paragraph 3 3 and hold a glass up to the light at the end of the cycle The drops of water on the glass will indicate insufficient dosage while streaks will indicate that dosage is excessive either in relation to density or quantity Regulate by means of the plug 20 turning cl...

Page 11: ...peration has been completed put the switch A in position 0 drain the tank pulling out the overflow pipe close the front door and put the switch A in position 1 for a few minutes making the cleaning of the machine easier For machines with drain pump pull out the overflow pipe then with closed door and machine switched on push button N for the drain cycle will be indicated by the switching on the S ...

Page 12: ...oughly clean the inside parts of the machine 2 Remove the filter 22 from the bottom of the machine by releasing the overflow 21 3 Wash the filters under running water and fit them correctly back in their housings ATTENTION Frequently check and clean the spraying units removing them from their housings and eliminating any dirt and fouling The frequency with which this operation must be carried out ...

Page 13: ...ure insufficient Incorrectly positioned nozzles or nozzles deformed Turn on the switch Turn on the cock Detach the fill pipe 12 Fig 6 and clean the filter 13 Unscrew and clean the nozzles 30 Fig 10 under running water Make sure that the overflow pipe 21 Fig 10 has been correctly inserted Clean the filter 22 Fig 10 Demount and clean the washing nozzles under running water Demount and clean the rod ...

Page 14: ...14 Fig 5 16 11 Fig 6 Fig 7 15 10 13 12 14 12 9 Mod R HOONVED s r l Via U Foscolo 21040 Venegono Sup re VA ITALIA Matr Max M IP ...

Page 15: ...15 21 30 22 25 24 28 23 28 29 Fig 10 Fig 9 A B1 2C D E 53 BT START R A B1 2C D E A B1 2C D E N 60 BT 60 BT PS START R START R S ...

Page 16: ...18 53 60 BT HOONVED s r l Via U Foscolo 21040 Venegono S VA ITALY Tel 0331 856111 Fax 0331 865223 R 5402 ...

Reviews: