__________________________________________________________________________________________________
_____________________________________________________________________________________
4/17
U398_UVATP_B_e_190425
Operating Instructions Transducer UVATP
in AS102 Housing
4.1 Description, Type Plates
Remove the cover to display one of the following type plates:
S/N.
: ...
: serial number
Type
: UVATP
: for vortex VA measuring tubes, temperature, pressure
Power
: 24 V DC
: supply voltage
24 V direct voltage current
12 V DC
: supply voltage 12 V direct voltage current
Output A1
: precision 4 ... 20 mA : analog output with high precision current 4 ... 20 mA
precision
0 ... 10 V : analog output with high precision voltage 0 ... 10V
Output A2
: fast
4 ... 20 mA : analog output with short time constant current 4 ... 20 mA
fast
0 ... 10 V : analog output with short time constant voltage 0 ... 10V
Input
: VADi
: for vortex VA measuring tubes (separate transducers only)
RS232
: RJ22 plug
: for serial PC interface
5 Technical Specifications
5.1 Conformity with Standards
The UVATP is manufactured according to the best available technology, is both safe and reliable
and complies with the relevant regulations, EU directives and standards.
5.2 Storage Conditions
Storage temperature: -30 bis +70 °C
5.3 Operating Conditions
Ambient temperature during operation with LCD display: -20 to +50 °C
protection class: IP65
mounting attitude: no restrictions, preferably with cable bush facing down.
separate UVATP
integrated UVATP