LED Powerline ACIC
18
#078734DE-EN e
4.2. PLD terminal
The PLD terminal allows the customer to control the LED module.
4.2.1.PLD terminal connections
5
Customer PLC interface
8
power supply
6
Connector for optional display (diagnosis)
9
fuse (10A)
7
SUB-D socket for
LED Powerline AC/IC
10
Diagnosis LEDs
4.2.2.Customer PLC interface (5)
PIN
Bezeichnung
Funktion
Diagnose LED
1
SPS_U
B
SPS U
B
IN (24V)
2
SPS_enable
SPS Input enable
EN
3
SPS_ON
SPS Input LED ON
ON
4
Fan_PWM
fan control (optional)
5
GND
GND
6
OUT_OK
SPS output LED U
B
OK
OK
7
OUT_OFF
SPS output LED is OFF
ISOFF
8
OUT_ON
SPS output LED is ON
ISON
9
not connected
10
not connected
11
GND
analogue set point
GND
12
GND
analogue set point
input
0
– 10V
≙
0
– 100%
13
GND
GND
PLD terminal
connections
Customer PLC
interface
9
8
5
6
7
10
1
1
10
13
GND
│ GND │ 48-54V