background image

 

direct contact with skin and eyes. Serious burns 

can result from some drain cleaning compounds. 
• Do not operate machine if operator or machine 

is  standing  in  water.  Will  increase  the  risk  of 

electrical shock. 
• Wear safety glasses and rubber soled, non-slip 

shoes. Use of this safety equipment may prevent 

serious injury. 
• Only use the A75 to clean drain lines up to 4″ in 

diameter.  Follow  instructions  on  the  use  of  the 

machine.  Other  uses  or  modifying  the  drain 

cleaner  for  other  applications  may  increase  the 

risk of injury. 

 

Description, Specifications and 

Standard Equipment 

Description 

The  A75  is  a  portable  Drain  Cleaning  Machine 

designed  to  clean  11/4

”  to  4”  drain  lines. 

Applications  include  sink,  shower  and  floor 

drains.  Capable  of  running  three  different  size 

cables: 5/16

” and 5/8”. 

The machine is driven by a 300W motor that has 

a  grounded  electrical  system.  A  toggle  switch 

provides  FORWARD/OFF/REVERSE  control  of 

the motor. 

The  A75  is  designed  to  use  5/8

”(16mm) 

diameter  sectional-type  cable  that  has  a  quick 

change coupling system for disconnecting tools. 

The cable is manually fed in and out of the drain 

and rotates at a speed of 400 RPM. The rotation 

of the cable is controlled by a clutch handle. The 

cable  stops  instantly  when  the  clutch  handle  is 

released. 

The A75 is also designed to use with the adapter 

which hold 5/16

”(8mm) continuous length cables. 

Rotation of the adapter is controlled by the clutch 

handle.  The  cable  adapter  is  equipped  with  a 

quick-acting  brake  which  immediately  stops 

rotation  of  the  drum  when  the  clutch  handle  is 

pulled upward. 

 

Specifications 

Line  Capacity  ...............Depends  on  choice  of 

cable. 

Cable Sizes ..................5/16

”(8mm) ,5/8”(16mm) 

Motor  Type  ..............................115V/50-60  Hz, 

Reversible, 230V Available Upon Request 

Rating ............................300W 

Amps .............................3A/1.75A 

Weight...........................14KG 

Dimensions 

Length ........................... 200mm 

Height ............................440mm 

Width ............................. 335mm 

 

Machine Inspection 

To prevent serious injury, inspect your Drain 

Cleaning  Machine.  The  following  inspection 

procedures 

should be performed before each use. 

1.  Make  sure  the  Drain  Cleaning  Machine  is 

unplugged and the directional switch is set to the 

OFF 

position.(Figure 1) 

2. Inspect the power cord and plug for damage. 

If  the  plug  has  been  modified,  is  missing  the 

grounding  prong  or  if  the  cord  is  damaged,  do 

not  use  the  Drain  Cleaning  Machine  until  the 

cord has been replaced. 

3.  Inspect  the  Drain  Cleaning  Machine  for  any 

broken,  missing,  misaligned  or  binding  parts  as 

well as any other conditions which may affect the 

safe and normal operation of the machine. If any 

of  these  conditions  are  present,  do  not  use  the 

Drain  Cleaning  Machine  until  any  problem  has 

been repaired. 

 

 

 

 

 

 
 
Fig 1 

Power switch 

Summary of Contents for A75

Page 1: ...ng Machine Operation Manual WARNING Read this Operator s Manual carefully before using this tool Failure to understand and follow the contents of this manual may result in electrical shock fire and or serious personal injury ...

Page 2: ...rease the risk of electrical shock When operating a tool outside use an outdoor extension cord marked W A or W These cords are rated for outdoor use and reduce the risk of electrical shock Use only three wire extension cords which have three prong grounding plugs and three pole receptacles which accept the tool s plug Use of other extension cords will not ground the tool and increase the risk of e...

Page 3: ...cidents are caused by poorly maintained tools Use only accessories that are recommended by the manufacturer for your model Accessories that may be suitable for one tool may become hazardous when used on another tool Keep handles dry and clean free from oil and grease Allows for better control of the tool Service Tool service must be performed only by qualified repair personnel Service or maintenan...

Page 4: ...andle The cable stops instantly when the clutch handle is released The A75 is also designed to use with the adapter which hold 5 16 8mm continuous length cables Rotation of the adapter is controlled by the clutch handle The cable adapter is equipped with a quick acting brake which immediately stops rotation of the drum when the clutch handle is pulled upward Specifications Line Capacity Depends on...

Page 5: ...ng procedures should be followed to set up the machine Set Up For 5 8 Sectional Cable 1 Check work area for Adequate lighting Grounded electrical outlet Clear path to the electrical outlet that does not contain any sources of heat or oil sharp edges or moving parts that may damage electrical cord Dry place for machine and operator Do not use the machine while standing in water Flammable liquids va...

Page 6: ...ting cloth or leather glove that may become wrapped around the cable causing serious injury Always wear eye protection to protect your eyes against dirt and other foreign objects Wear rubber soled non slip shoes Be very careful when cleaning drains where cleaning compounds have been used Wear gloves when handling cable and avoid direct contact to the skin and especially the eyes and facial area as...

Page 7: ... WARNING Do not allow tension to build up in the cable This will happen if the cutting tool hits a snag and stops turning but the motor and cable continue to rotate Torque builds until the cable suddenly twists potentially wrapping around your hand or arm This can happen quickly and without warning so proceed slowly and carefully as you feed the cable into the drain Releasing clutch handle will st...

Page 8: ...l it stops feeding easily Push cable down drain line keeping your control hand close to the drain opening 3 Hold cable loosely in mittened hand put FOR OFF REV SWITCH in FOR forward position NOTE The motor will start but cable will not rotate 4 With mitted hand on cable push down on clutch handle with opposite hand to engage adapter 5 Continue hand feeding the cable slowly until the drain is opene...

Page 9: ...cate cables and couplings When not in use store cables indoors to prevent deterioration by the elements Cables should be replaced when they become severely corroded or worn A worn cable can be identified when outside of coils become flat Cable Containers Cable container on 5 16 cable adapter should be periodically cleaned 1 Remove cable from the cable adapter Cable is not attached to inside of dru...