3
direct contact with skin and eyes. Serious burns
can result from some drain cleaning compounds.
• Do not operate machine if operator or machine
is standing in water. Will increase the risk of
electrical shock.
• Wear safety glasses and rubber soled, non-slip
shoes. Use of this safety equipment may prevent
serious injury.
• Only use the A75 to clean drain lines up to 4″ in
diameter. Follow instructions on the use of the
machine. Other uses or modifying the drain
cleaner for other applications may increase the
risk of injury.
Description, Specifications and
Standard Equipment
Description
The A75 is a portable Drain Cleaning Machine
designed to clean 11/4
” to 4” drain lines.
Applications include sink, shower and floor
drains. Capable of running three different size
cables: 5/16
” and 5/8”.
The machine is driven by a 300W motor that has
a grounded electrical system. A toggle switch
provides FORWARD/OFF/REVERSE control of
the motor.
The A75 is designed to use 5/8
”(16mm)
diameter sectional-type cable that has a quick
change coupling system for disconnecting tools.
The cable is manually fed in and out of the drain
and rotates at a speed of 400 RPM. The rotation
of the cable is controlled by a clutch handle. The
cable stops instantly when the clutch handle is
released.
The A75 is also designed to use with the adapter
which hold 5/16
”(8mm) continuous length cables.
Rotation of the adapter is controlled by the clutch
handle. The cable adapter is equipped with a
quick-acting brake which immediately stops
rotation of the drum when the clutch handle is
pulled upward.
Specifications
Line Capacity ...............Depends on choice of
cable.
Cable Sizes ..................5/16
”(8mm) ,5/8”(16mm)
Motor Type ..............................115V/50-60 Hz,
Reversible, 230V Available Upon Request
Rating ............................300W
Amps .............................3A/1.75A
Weight...........................14KG
Dimensions
Length ........................... 200mm
Height ............................440mm
Width ............................. 335mm
Machine Inspection
To prevent serious injury, inspect your Drain
Cleaning Machine. The following inspection
procedures
should be performed before each use.
1. Make sure the Drain Cleaning Machine is
unplugged and the directional switch is set to the
OFF
position.(Figure 1)
2. Inspect the power cord and plug for damage.
If the plug has been modified, is missing the
grounding prong or if the cord is damaged, do
not use the Drain Cleaning Machine until the
cord has been replaced.
3. Inspect the Drain Cleaning Machine for any
broken, missing, misaligned or binding parts as
well as any other conditions which may affect the
safe and normal operation of the machine. If any
of these conditions are present, do not use the
Drain Cleaning Machine until any problem has
been repaired.
Fig 1
Power switch