General safety instructions
Contents
1. General
safety
instructions
.................................... 5
1.
General safety instructions
........... 5
1.1.
Commissioning the relay module HC60NG
1.1.
Commissioning the relay module
HC60NG
............................................................... 6
2.
Overview
............................. 6
2.1.
Pre configured kit Y6630D1007
2.2.
Singly provided devices......................................... 6
DANGER
Danger to life due to electric shock!
3.
Installation ............................................................. 6
Contacts that are open are live.
3.1.
Installation relay module HC60NG ........................ 6
►
Ensure that the device is de-
energised.
3.1.1.
Connections for HC60NG (R6660D1009) ............. 7
3.2.
Installation room unit HCW 80............................... 8
►
Have all the work carried out by
authorised qualified personnel.
4.
Checking ............................................................... 9
4.1.
System check ........................................................ 9
►
Observe the valid local regulations
during the installation.
..................................... 9
4.2.
Radio transmission check
................ 9
5.
Teach-in (singly provided devices only)
WARNING
Insufficient data transfer!
5.1.
Assignment to the relay module HC60NG............. 9
Interference of the relay module
HC60NG in the device due to metallic
objects or further frequency devices.
5.2.
Failed teach-in....................................................... 9
6.
Communication loss .............................................. 9
7.
Factory reset of relay module HC60NG ................ 9
►
Mount the device with a distance of at
least 30 cm to metallic objects such
as wall boxes or boiler housings
according to the DECT standard, etc.
8.
Particular features of the room unit HCW 80....... 10
8.1.
Operation ............................................................ 10
8.2.
Limiting the adjustment range ............................. 10
8.3.
Fixed control parameters..................................... 10
►
Do not mount on metal wall boxes.
.............................................. 10
9.
Changing batteries
WARNING
Damage to the device!
10.
Appendix ............................................................. 11
Short-circuiting due to humidity and
moisture.
10.1.
Help with problems.............................................. 11
10.2.
Specifications HCW 80........................................ 11
►
Mount the device at a site that is
protected against humidity and
moisture.
10.3.
Specifications HC60NG....................................... 11
10.4.
Approvals ............................................................ 11
10.5.
Device and function definition in accordance
with EN 60730-1.................................................. 11
WARNING
Damage to exposed components!
10.6.
WEEE directive 2012/19/EC................................ 11
Destruction of the electronic
components due to electrostatic
discharges.
10.7.
Declaration of Conformity.................................... 12
►
Do not touch the components.
►
Touch an earthed piece of metal to
discharge static electricity from your
body.
5
Summary of Contents for Y6630D1007
Page 2: ......
Page 3: ...ENGLISH 5 DEUTSCH 13 FRANÇAIS 21 NEDERLANDS 29 POLSKI 37 ROMÂN 45 ...
Page 4: ......
Page 53: ......