INSTALLATION INSTRUCTIONS

69- 1304

VS8420C,M

 Millivolt Gas Valve

APPLICATION

The VS8420 Millivolt Gas Valve is compact and has a 
low capacity.  The design makes it ideal for central heat-
ing, fireplace, and space heating applications.

The VS8420 Millivolt Gas Valve is approved in accor-
dance with existing European standards.

SPECIFICATIONS

Main Gas Connection:
Valve:3/8" ISO 7/1 internal thread for 12 mm outside 

diameter tube.
Inlet connection at inlet side or at bottom.
Outlet connection at outlet side or at bottom.

Pilot Gas Connection and Flow:
Connection Size: M10 x 1 for 4 or 6 mm outside diame-

ter tube. At inlet side or at bottom.  

Flow: Adjustable from 0.014 m3/h air at 35 mbar inlet 

pressure to 0.105 m3/h at 7.5 mbar.  

Thermocouple and Pilot Threads:
Metric and UNS.
Thermocouple connection: M10 x 1 at bottom. Optional at 

the outlet side with use of a thermocouple re-route. 

Ambient Temperature Range: 0°C to 80

°

C (32°F to 

175°F).

Maximum Inlet Pressure: 60 mbar (24 in. wc)

Pressure Regulation (Standard Regulator):
Servo regulator with adjustable outlet pressure; in 

accordance with EN 88, class C.

Natural Gas: 9 mbar, typical. 
LP: 27 mbar, typical.

Regulator Adjustments (Standard Regulator):
Natural Gas: 7.5 mbar to 12.5 mbar field adjustable.
LP: 20 mbar to 30 mbar field adjustable.

In appliances where no regulation is required, the pres-
sure regulator must be blocked by turning the pressure 
regulator adjustment screw fully down. The regulator 
will then be set at 30 mbar.

Voltage: VS8420: 750 mV operator, 30 mV thermocou-

ple.

Approvals: European Community (CE) Certificate: CE-
0063AU1270.  

Other Features:
Pressure Tap: 9 mm outside diameter at inlet and outlet 

sides in accordance with EN 126.

Screen: Fine mesh inlet screen.
Interrupter (ECO) Connection: 6.3 mm tab connectors.
Piezo Sparker: Optional piezo sparker. 

INSTALLATION

When Installing this Product...

1.

Read these instructions carefully. Failure to follow 
them could damage the product or cause a haz-
ardous condition.

2.

Check the ratings given in the instructions and on 
the product to make sure the product is suitable 
for your application.

3.

Installer must be a trained, experienced service 
technician.

4.

After installation is complete, check out product 
operation as provided in these instructions.

WARNING

Oxygen Depletion Hazard.
Can cause injury or death due to asphyxia-
tion.
Use only vented gas valve models on vented 
appliances. Use only unvented gas valve mod-
els on unvented appliances.

Summary of Contents for VS8420C

Page 1: ...ith EN 88 class C Natural Gas 9 mbar typical LP 27 mbar typical Regulator Adjustments Standard Regulator Natural Gas 7 5 mbar to 12 5 mbar field adjustable LP 20 mbar to 30 mbar field adjustable In appliances where no regulation is required the pres sure regulator must be blocked by turning the pressure regulator adjustment screw fully down The regulator will then be set at 30 mbar Voltage VS8420 ...

Page 2: ...onvert from natural gas to LP High low regulator model VS8420C cannot be converted Location Locate the combination gas valve where it cannot be affected by steam cleaning high humidity dripping water corrosive chemicals dust or grease accumula tion or excessive heat To assure proper operation follow these guidelines Locate gas valve in a well ventilated area Mount gas valve high enough to avoid ex...

Page 3: ...pilot burner according to the manufacturer s instructions WARNING Fire or Explosion Hazard Can cause property damage severe injury or death Do not bend tubing at gas valve after compres sion fitting has been tightened as this may result in a gas leak at the connection Fig 3 Top view of gas valve with HI LO regulator Fig 4 Top view of gas valve with standard regulator GAS CONTROL GAS CONTROL HORIZO...

Page 4: ...ting stamped on the valve operator Table 1 Maximum Thermostat Wire Length ECO Connection Supplementary 1 Push the ECO into the window of the gas valve See Fig 5 2 The leadwires of the ECO must be equipped with insulated 6 3 mm female quick connect terminals 3 Leadwire length must not exceed the length as shown in Table 2 Table 2 Maximum Length mm of Supplementary Limit Leadwires When Using Q309A T...

Page 5: ...erclockwise to the ON position On a call for heat the main valve opens and the main burner ignites Shut off Procedure 1 To shut off the system turn the knob clockwise to the OFF position This action closes the main gas and safety valves however the power unit must drop out before the lighting sequence can begin again The VS8420 drops out within 30 seconds 2 To relight the pilot light follow the st...

Page 6: ...ot gas flow Gas valve and thermostat control main burner gas flow PILOT Opens pilot valve and allows gas flow to the pilot burner HI LO Manually adjusts outlet pressure NOTE Valves are shipped with the gas control knob in the ON position Perform Gas Leak Test WARNING Fire or Explosion Hazard Can cause property damage severe injury or death Stand away from the main burner while lighting Hidden gas ...

Page 7: ...equipment operates 100 000 to 200 000 cycles per year This heavy cycling can wear out the gas valve in one to two years Exposure to water dirt chemicals and heat can damage the gas valve and shut down the control system The maintenance program should include regular system checkout as outlined in the Checkout section and checkout of the control system as described in the appliance manufacturer lit...

Page 8: ...ff the manual valve in the gas piping to the appliance or on LP at the tank Leave the building immediately and call your gas supplier If your gas supplier cannot be reached call the fire department 3 Do not force the gas valve control knob Use only your hand to turn the control knob 4 If the knob does not operate by hand the valve should be replaced by a qualified service techni cian 5 The gas val...

Reviews: