Printed in U.S.A.
IMPORTANT: Follow the operating instructions pro-
vided by the manufacturer of your heating appliance.
The information below will be of assistance in a
typical gas control application, but the specific con-
trols used and the procedures outlined by the manu-
facturer of your appliance may differ and require
special instructions.
STOP: READ THE WARNINGS ABOVE.
If the appliance does not turn on when the thermostat is
set several degrees above room temperature, follow these
instructions:
1. Set the thermostat to its lowest setting to reset the
safety control.
2. Disconnect all electric power to the appliance.
3. Remove the gas control access panel.
4. Push in the gas control knob slightly and turn
clockwise
to OFF.
5. Wait five minutes to clear out any unburned gas. If
you then smell gas, STOP! Follow step 2 in the Warning
in the Instructions To The Homeowner section. If you do
not smell gas, continue with the next step.
6. Turn the gas control knob counterclockwise
to
ON.
7. Replace the gas control access panel.
8. Reconnect all electric power to the appliance.
9. Set the thermostat to the desired setting.
10. If the appliance does not turn on, set the gas control
knob to OFF and contact a qualified service technician for
assistance.
TURNING OFF THE APPLIANCE
VACATION SHUTDOWN—Set the thermostat to the
desired room temperature while you are away.
COMPLETE SHUTDOWN—Push in the gas control knob
slightly and turn clockwise
to OFF. Do not force.
Appliance will completely shut off. Follow the In-
structions to the Homeowner above to resume normal