Honeywell V8200A Installation Instructions Manual Download Page 8

V8200A,C,H,M AND VR8200A,C,H,M CONTINUOUS PILOT COMBINATION GAS CONTROLS

Automation and Control Solutions

Honeywell International Inc.
1985 Douglas Drive North
Golden Valley, MN  55422

Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Toronto, Ontario  M1V 4Z9
customer.honeywell.com

® U.S. Registered Trademark
© 2011 Honeywell International Inc.
69-0422—03   M.S.  Rev. 01-11
Printed in U.S.A.

If your gas supplier cannot be reached, call the 
fire department.

Do not force the gas control knob on the 
appliance. Use only your hand to push down the 
reset button or turn the gas control knob. Never 
use any tools. If the knob or reset button will not 
operate by hand, the control should be replaced 
by a qualified service technician. Force or 
attempted repair may result in fire or explosion.

The gas control must be replaced if it has been 
flooded with water. Call a qualified service 
technician.

If the red reset button stays depressed after it is 
released, the gas control should be replaced.

The gas control is a safety device. It must be 
replaced in case of any physical damage such as 
bent terminals, missing or broken parts, stripped 
threads, or evidence of exposure to heat.

IMPORTANT

Follow the operating instructions provided by 
the manufacturer of your heating appliance. The 
information below will be of assistance in a 
typical control application, but the specific 
controls used and the procedures outlined by 
the manufacturer of your appliance may differ, 
requiring special instructions.

To Light The Pilot Burner

STOP: Read the safety information 
above.

1.

This appliance has a pilot burner which must be lit 
by hand. If the pilot flame has gone out, follow 
these instructions exactly.

2.

Set thermostat to lowest setting and shut off elec-
tric power to appliance.

3.

Remove burner access panel if provided on your 
appliance.

4.

Turn gas control knob (Fig. 4) clockwise 

 to 

OFF position.

5.

Wait five minutes to allow any gas in the 
combustion chamber to vent. If you then smell gas 
in the appliance area or near the floor in an LP 
installation, immediately shut off the manual valve 
in the gas piping to the appliance or, WITH LP, AT 
THE TANK. Don't touch any electrical switch or use 
the phone. LEAVE THE BUILDING and call your 
gas supplier. If your gas supplier cannot be 
reached, call the fire department. Failure to do so 
may result in fire or explosion.

6.

If you don't smell gas, turn knob on gas control 
counterclockwise 

 to PILOT.

7.

Push and hold down red reset button (Fig. 4) while 
you light the pilot burner. Continue to hold the reset 
button down for about one minute after the pilot is 
lit. Release button; pilot should remain lit. If it goes 
out, repeat steps 4-7. If the reset button does not 
pop up when released, stop immediately and call 
your service technician or gas supplier. If pilot will 
not remain lit after several tries, turn gas control 
knob to OFF and call your service technician or 
gas supplier.

8.

When pilot remains lit, turn gas control knob 
counterclockwise 

 to ON.

9.

Replace burner access panel.

10.

Turn on power.

11.

Set thermostat to desired temperature.

To Turn Off Appliance

Vacation shutdown…turn gas control knob clockwise 

 from ON to PILOT. Pilot will remain lit, ready for 

return to normal service without relighting.

Complete shutdown…turn gas control knob clockwise 

 to OFF. Both pilot and main burner are shut off. The 

pilot must be manually relit when normal burner 
operation is desired.

Tradeline

® 

is a registered trademark of Honeywell Internatinal Inc.

Teflon™ is a trademark if E.I. DuPont De Nemous and Company.

Summary of Contents for V8200A

Page 1: ... one gas to the other with a conversion kit order separately Order Part No 393691 to convert from natural manufactured to LP gas order Part No 394588 to convert from LP to natural manufactured gas Controls with step opening regulators cannot be converted CSA Certificate 112395 Australian Gas Association Certificate 4752 Table 1 Continuous Pilot Combination Gas Control Models Table 2 Model Number S...

Page 2: ... valve coil terminals This may burn out the heat anticipator in the thermostat IMPORTANT These gas controls are shipped with protective seals over inlet and outlet tappings Do not remove seals until ready to connect piping Follow the appliance manufacturer s instructions if available otherwise use the instructions provided below as a guide Convert between Natural and LP Gas WARNING Fire or Explosi...

Page 3: ... ordinances or with the Natural Fuel Gas Codes ANSI Z223 1 NFPA No 54 whichever applies Tubing installation must comply with approved standards and practices 1 Use new properly reamed pipe free from chips If tubing is used make sure the ends are square deburred and clean All tubing bends must be smooth and without deformation 2 Run pipe or tubing to the control If tubing is used obtain a tube to p...

Page 4: ...onnection and must be clean and dry Never use pipe compound Tighten only 1 4 turn beyond finger tight to give good electrical continuity DO NOT OVERTIGHTEN Wiring Follow the wiring instructions furnished by the appliance manufacturer if available or use the general instructions provided below Where these instructions differ from the appliance manufacturer s follow the appliance manufacturer s inst...

Page 5: ...h main burner in operation paint pipe joints including adapters and control inlet and outlet with rich soap and water solution 5 If another leak is detected tighten adapter screws joints and pipe connections 6 Replace part if leak can t be stopped Light Pilot 1 Rotate the gas control knob clockwise to OFF Wait five minutes to allow any unburned gas to dissipate Sniff around the appliance near the ...

Page 6: ...as control Refer to Fig 4 3 If necessary adjust pressure regulator to match appliance rating Refer to Table 7 for factory set nominal outlet pressure and adjustment range a Remove pressure regulator adjustment cap and screw b Using screwdriver turn inner adjustment screw clockwise to increase or counterclockwise to decrease gas pressure to burner c Always replace cap screw and tighten firmly to en...

Page 7: ...stment see page 6 3 Check the connection to the power unit This is an electrical connection and must be clean and secure 4 If pilot still goes out use a millivoltmeter to measure the exact open circuit output voltages of the thermocouple Compare to acceptable range charts in the thermocouple specifications Replace the thermocouple if voltages are outside the acceptable range otherwise replace the ...

Page 8: ...instructions exactly 2 Set thermostat to lowest setting and shut off elec tric power to appliance 3 Remove burner access panel if provided on your appliance 4 Turn gas control knob Fig 4 clockwise to OFF position 5 Wait five minutes to allow any gas in the combustion chamber to vent If you then smell gas in the appliance area or near the floor in an LP installation immediately shut off the manual ...

Reviews: