high capacity 1 in. BSPP by 1 in. BSPP gas control.
THERMOCOUPLE REQUIRED (ordered separately) for
24V, 100V, 120V, and
models: Q309 orQ340
suggested.
Nominal output: 30 mV, 0.02 ohms,
Open circuit turndown voltage: 2mV.
POWERPILE GENERATOR REQUIRED (order sepa-
rately) for 75o
models: Q302 or Q313 suggested.
Nominal output: 750 mV, 3.4 ohms.
Open circuit turndown voltage: 141 mV.
OPTIONAL SPECIFICATIONS:
1. Inlet pressure tap, 1/8 in. NPT.
2. Side outlets.
REPLACEMENT PARTS:
1.392451-1 Energy Cutoff
Connector.
2. Valve Operators:
Powerpile Operator: VS824.
operator with modulating control: V5306.
3. Servo Gas Pressure Regulators.
Standard pressure regulator: V5306.
Step-opening pressure regulator: V5307.
WHEN INSTALLING THIS PRODUCT...
Read these instructions carefully. Failure to follow
instructions can damage product or cause a hazardous
condition.
2. Check ratings given in instructions and on product to
make sure product is suitable for your application.
3. Make sure installer is a trained, experienced service
technician.
4. After completing installation, use these instructions to
check out product operation.
FIRE OR EXPLOSION HAZARD
CAN CAUSE PROPERTY DAMAGE, SEVERE
INJURY, OR DEATH
Follow these warnina
2.
3.
4.
To avoid
accumulation of fuel gas,
turn off gas supply at appliance service valve
before starting installation and perform Gas
Leak Test after completion of installation.
Do not bend pilot tubing at the
or
after compression nut has been tightened.
Gas
at the connection may
Aiways
sediment trap in gas
line to prevent contamination of gas
Do not force gas
knob. Use oniy your
hand to turn gas
knob. Never use any
tools. if gas
knob
not operate by
hand, the
be
by a
service technician. Force or at-
tempted repair may
in fire or
1. Disconnect power supply before wiring to prevent
electrical shock or equipment damage.
2. Never apply a jumper across (or short) valve coil
terminals. This may burn out heat anticipator in
thermostat.
IMPORTANT
These gas
are shipped with protective seals
over inlet and
tappings. Do not remove seals
until ready to connect piping.
OPTiONAL
TRADELiNE MODELS
To facilitate installation, TRADELINE models incorpo-
rate side outlets in the standard straight-through body.
Refer to Fig. 3.
To fit existing piping, reducer fittings also are included.
These controls are shipped with side outlets plugged as
shown. if connection is made to optional side
be
sure to install plug in standard straight-through outlet
tapping. Use plug removed from side outlet.
Perform Gas Leak Test when installation is complete.
LEFT SIDE
OUTLET
M A N
UAL GAS
CONTROL KNoB \
OUTLET
INLET
STRAIGHT
WRENCH
THROUGH
BOSS
RIGHT
9
OUTLET
FiG. 3—TRADELiNE
SiDE OUTLETS (stan-
dard capacity models
Follow appliance manufacturer’s instructions if avail-
able; otherwise, use instructions provided below as a
guide.
LOCATiON
Do not
the combination gas
where ad-
verse environments such as steam cleaning, high humidity
or dripping water, corrosive chemicals, dust or grease ac-
cumulation, or excessive heat are prevalent. To ensure
proper operation, follow these guidelines:
●
Locate in a well ventilated area.
●
Mount high enough above the cabinet bottom to
avoid exposure to flooding or splashing water.
●
Ensure that the ambient temperature does not ex-
ceed the ambient temperature ratings for each
component.
●
Cover if appliance is cleaned with water, steam, or
chemicals
accumulation.
●
Avoid
where exposure to corrosive
cai fumes or dripping water is
Mount the combination gas control in the
ves-
tibule on the gas manifold. if this is a replacement applica-
tion, mount the control in same location as old control.
60-2019-7