HZ322 TrueZONE

 

1 69-2199—05

APPLICATION

ACCESSORIES

Table 1. Recommended Thermostats.

System Non-

Programmable

Programmable

Single-

Stage

TH5110D, 

TH3110D, T87N

TH8110U, 

TH6110D, TH4110D

Multi-

Stage

TH5220D

TH8320U, TH8321U, 

TH6220D, 

YTH9421C

Heat-

Pump

TH5220D 

TH3210D

TH8320U 

TH8321U 

TH6220D 

TH4210D 

YTH9421C

Wire-

less*

TH5320R

TH6320R

Note:

 All versions of the model numbers listed 

above will work with the applications they're listed 

for.

* For RedLINK™ wireless devices, a THM4000 is 

required.

Table 2. Recommended Dampers.

Type

Honeywell 

Damper

Round Rectangular

Zone

Spring-open/

power-closed

ARD  

(8 VA)

ZD (8 VA)

Power-open/

power-closed

MARD/

RRD  

(2 VA)

For recommend-

ed dampers call 

the Honeywell 

Zoning Hotline at 

1-800-828-8367.

Bypass Static pres-

sure regulat-

ing damper

SPRD/

MARD 

(2 VA)

SPRD

Table 3. Recommended Commercial Dampers.*

Type

Actuation

Round

Rectangular

Zone

Power-open/

power-closed

MARD

D2 or D3 with 

ML6161A2009*

Bypass Power-open/

power-closed

MARD 

with 

SPC

D3 with 

ML6161B2024* 

and SPC

* Or equivalent damper and actuator.

Table 4. Maximum Dampers.*

Ambient Temp.

Maximum Damper VA per Zone

100°F (38°C)

28.8

160°F (71°C)

16.8

* Use an SDCR (Slave Damper Control Relay) for addi-

tional dampers.

  Maximum dampers per panel is limited by transform-

er size.

  Ensure transformer is large enough to power the 

panel (7.5 VA) and dampers.

Table 5. Accessories.

Accessory

Description

40 VA transformer*

AT140A1042*

75 VA transformer

AT175A1008

Discharge Air 

Temperature Sensor *

DATS C7735A1000*

SDCR**

Slave Damper Control 

Relay

Wireless Adapter***

THM4000R1000

Wireless Outdoor Air 

Temperature Sensor***

C7089R1013

Portable Comfort 

Control***

REM5000R1001

RedLINK Internet 

Gateway***

THM6000R1002

*   Included in HZ322K kit.

**  Use an SDCR (Slave Damper Control Relay) to 

add additional dampers to a zone to surpass the 

maximum Damper VA rating per Zone.

*** For RedLINK™ wireless devices, a THM4000 is 

required.

The HZ322 TrueZONE

®

 panel controls:

• 

Conventional gas, oil, or electric forced-air systems up to 2 stages heat and cool;

• 

Heat pump systems with single stage compressor and auxiliary heat, and two stage heat pumps with no 
auxiliary heat; and two stage heat pumps with no auxiliary heat;

• 

2 or 3 forced-air zones with wired thermostats, or wireless thermostats using THM4000R wireless adapter.

Please refer to TrueZONE Panel Frequently Asked Questions form 50-9694 for operating details.
http://customer.honeywell.com

Summary of Contents for TRUEZONE HZ322

Page 1: ...HZ322 TrueZONE Zone Panel Professional Installation Guide 69 2199 05 ...

Page 2: ...90 RH non condensing Temperature Ratings Shipping 20 to 150 F 29 to 66 C Operating 40 to 165 F 40 to 74 C Dimensions See below Emissions Complies with FCC Class B part 15 requirements Read and save these instructions Need Help For assistance with this product please visit http customer honeywell com and or call Honeywell Zoning Hotline toll free at 1 800 828 8367 U S Registered Trademark US Patent...

Page 3: ...r Zone 100 F 38 C 28 8 160 F 71 C 16 8 Use an SDCR Slave Damper Control Relay for addi tional dampers Maximum dampers per panel is limited by transform er size Ensure transformer is large enough to power the panel 7 5 VA and dampers Table 5 Accessories Accessory Description 40 VA transformer AT140A1042 75 VA transformer AT175A1008 Discharge Air Temperature Sensor DATS C7735A1000 SDCR Slave Damper ...

Page 4: ...se and use the base as a template to drill mounting holes Attach the base to the wall stud roof truss or duct with appropriate screws not included Use two screws for attaching to a stud or roof truss or four screws for duct or drywall plaster installations Fig 2 Fig 3 SUPPLY DUCT DATS AT LEAST 3 FT FROM PLENUM DATS ALTERNATE LOCATION TrueZONE PANEL MOUNTED ON RETURN DUCT TrueZONE PANEL MOUNTED ON ...

Page 5: ...zone panel To connect wire to the panel strip approximately 1 4 in of insulation and push wire into terminal To release wire press the button on top of the terminal In retrofit applications trim end of wire if not straight 3 Install dampers using instructions provided with dampers Connect dampers to zone panel NOTE Multiple dampers can be wired in parallel 4 M28023 Rc R C W W2 Y Y2 G M1 M4 M6 R C ...

Page 6: ... assistance with the DATS see the Discharge Air Temperature Installation Instructions Form Number 69 1521 5 Connect equipment as shown here and on page 5 and 6 6 C7735A1000 M28024 SENSOR DATS DATS 8 Connect a dedicated transform er as shown DEDICATED TRANSFORMER R C M24806 R C POWER L1 HOT L2 RH RC W1 E W2 Y1 Y2 G O B DS BK M28025 HVAC FAN RELAY 24 VOLT TRANS G Y Y2 C R W COMPRESSOR RELAY W2 EQUIP...

Page 7: ...C W W2 Y Y2 G RC R C W W2 Y Y2 G RC R C W W2 Y Y2 G RH RC W1 E W2 Y1 Y2 G O B DS BK HZ322 HEAT 1 HEAT 2 COOL 1 COOL 2 FAN PURGE EM HEAT ZONE 1 ZONE 2 ZONE 3 EMERGENCY HEAT M1 M4 M6 R C W1 E W2 Y1 Y2 G O B L ZONE 1 DAMPER THERMOSTAT M1 M4 M6 R C W1 E W2 Y1 Y2 G O B L ZONE 2 DAMPER THERMOSTAT SENSOR DATS DATS EQUIPMENT R C POWER M1 M4 M6 R C W1 E W2 Y1 Y2 G O B L ZONE 3 DAMPER THERMOSTAT A B C D WIR...

Page 8: ...LIARY AND EMERGENCY HEAT JUMPER W1 E AND W2 4 ABCD TERMINALS FOR THE THM4000R WIRELESS ADAPTER ONLY NEVER WIRE A THM5320R WIRELESS EIM TO THESE TERMINALS 4 M4 OPEN M6 CLOSED M1 COMMON M28020 R C L1 HOT L2 AIR HANDLER FAN RELAY EM HEAT AUX HEAT G Y 24 VOLT TRANS C R E W2 C7735A1000 DATS HEAT PUMP Y C R DEDICATED TRANSFORMER ARD OR ZD DAMPER SPRING OPEN POWER CLOSED ARD OR ZD DAMPER SPRING OPEN POWE...

Page 9: ... CONVENTIONAL NON HEAT PUMP THERMOSTATS OPTIONS TSTAT TIMER ZONES OFF ADVANCED CONFIG NO YES SAVE CHANGES NO YES COMPRESSOR STAGES 1 2 1 2 3 1 AUX HT ENABLED YES NO SET TO YES IF WIRELESS RADIO FREQUENCY THERMOSTATS AND THM4000R ADAPTER ARE USED 2 YES OPTIONS 1 2 3 ZONES INSTALLED 3 OPTIONS 1 2 3 ASKS THIS FOR EVERY ZONE ZONES INSTALLED 3 RF YES ALLOWS YOU TO VIEW CHANGE THE ADVANCED CONFIGURATION...

Page 10: ...imit DAT HIGH LIMIT 110 F 180 F 160 F 110 deg F 180 deg F High temperature limit DATS Low Limit DAT LOW LIMIT 30 F 60 F 40 F 30 deg F 60 deg F Low temperature limit OT Temp Enabled OT SENSOR NO YES Disabled Enables or disables wireless outdoor tempera ture sensor If Disabled the Multistage OT Temp Lockout setting is Disabled NO YES Enabled OT Trip Point for Multistage Lockout OT LOCKOUT TEMP 0 F 5...

Page 11: ...til the Check out LED lights up Use the Adjust Setting and Next buttons to work through the checkout menu as listed below See the Configuration section on page 7 for instructions on using these buttons Steps 3 10 cycle through heating and cooling stages and open and close dampers to verify proper operation of the equipment and dampers These steps energize the equipment and damper terminals Steps 1...

Page 12: ...our 24 months from date of installation unless specified otherwise Variable frequency drive devices VFD and accessories new products for thirty six 36 months and factory refurbished drives for twelve 12 months from date of installation when start up and commissioning is performed by Honeywell VFD Authorized and trained personnel All VFD warranty return products must have prior authorization Form N...

Reviews: