Installation Recommendations and Options
SUPPLY
RETURN
AIR HANDLER
TrueDRY
M27325
A
Main Return to Main Return
M27327
E
Unducted
Ideal when…
• Running TrueDRY DH90 with A/C operation.
• Minimizing discharge air temperature (DAT) increase
is preferred.
• Space dictates.
SUPPLY
RETURN
AIR HANDLER
TrueDRY
M27324
BACKDRAFT
DAMPER
B
Main Return to Main Supply
Ideal when…
• Running TrueDRY DH90 opposite A/C operation.
Running with A/C operation requires damper on the
exhaust port to minimize backdraft when TrueDRY
DH90 is not on but A/C is.
• Minimizing DAT increase is preferred.
• Space dictates.
Ideal when…
• Drying a specific area of the house.
• Running with A/C operation requires backdraft
damper on the exhaust port to minimize backdraft
when TrueDRY DH90 is not on but A/C is.
• Minimizing DAT increase is preferred.
SUPPLY
RETURN
AIR HANDLER
TrueDRY
M27326
SEPERATE
RETURN
BACKDRAFT
DAMPER
C
Dedicated Return to Main Supply
Ideal when…
• Drying a specific conditioned or unconditioned area,
such as attic, basement, or crawl space.
• Balanced dehumidification is needed without
ventilation.
• Minimizing DAT is not a concern.
Ideal when…
• Running TrueDRY DH90 with A/C operation.
• Drying a specific area of the house.
• Minimizing DAT increase is preferred.
SUPPLY
RETURN
AIR HANDLER
M27601
TrueDRY
SEPERATE
RETURN
D
Dedicated Return to A/C Return