T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT

68-0196–1

8

b.

Press Select.
Press 

 or 

 to set

Return temperature.

6.

Sleep

a.

Press Select.
Press 

 or 

 to set

Sleep time.

b.

Press Select.
Press 

 or 

 to set

Sleep temperature.

Setting the Weekend Program

7.

Wake

a.

Press Select.
Press 

 or 

 to set

Wake time.

b.

Press Select.
Press 

 or 

 to set

Wake temperature.

8.

Leave

a.

Press Select.
Press 

 or 

 to set

Leave time.

b.

Press Select.
Press 

 or 

 to set

Leave temperature.

9.

Return

a.

Press Select.
Press 

 or 

 to set

Return time.

b.

Press Select.
Press 

 or 

 to set

Return temperature.

10.

Sleep

a.

Press Select.
Press 

 or 

 to set

Sleep time.

b.

Press Select.
Press 

 or 

 to set

Sleep temperature.

11.

End Programming.
Press Select. End is
displayed. Programming is
complete. The thermostat
will revert to displaying the
current day, time and
temperature in five
seconds.

NOTE:

To reset the thermostat to the preprogrammed time
and temperature settings (see Table 1):
a.

Press and hold the Hold and Select keys
simultaneously. The display will begin counting
down from 36 to zero.

b.

The thermostat display will go blank, then will
display the current time and temperature.

c.

Release keys, the program has reverted to the
preprogrammed time and temperature settings.

Setting Temperature Hold

Slide the SYSTEM switch to the heat or cool position.

Temporary Temperature Hold

1.

Press 

 or 

 key to select

a temporary temperature
setting.

NOTE:

The temporary temperature setting is displayed for
approximately 3 seconds and remains in effect until
the next program period. To cancel, press Hold twice.

Indefinite Temperature Hold

The Hold key allows you to indefinitely hold a temperature.
When Hold is active, the letters Hld are displayed continuously.
Hold can be canceled by pressing the Hold key again.

1.

Press Hold

 

2.

Press 

 or 

 key to select

indefinite temperature
setting.

NOTE:

Indefinite hold remains in effect until the Hold key is
pressed to cancel it.

M12629A

M12630A

M12631B

M12632A

M12633B

M12634A

M12636A

M12635A

M12637A

M12638A

M12639B

M12511A

M12640A

TEMPORARY

WED

PM

M12641A

Summary of Contents for TRADELINE T8011R

Page 1: ...er satisfaction Large temperature display for quick easy readability Conveniently sized thermostat 5 1 2 x 3 1 2 with optional decorator cover plates 7 3 8 x 5 3 4 make it easy to install in a variety of locations Keys are located by the display for easy access FAN and SYSTEM switches are located on the lower edge to eliminate accidental setting changes Easy installation setup and system checkout ...

Page 2: ...lplate for wiring and mounting thermostat and Owner s Guide Power T8011R 24 Vac nominal 18 to 30 Vac 50 or 60 Hz Electrical Ratings First Stage Heating 02 to 1 5A run 7 5A inrush Second Stage Heating 02 to 1 5A run 3 5A inrush Cooling 02 to 1 5A run 7 5A inrush Fan 02 to 0 5A run 2 5A inrush Emergency Heat Output E 02 to 1 5A run 3 5A inrush Heating Changeover Valve B 02 to 0 5A run 2 5A inrush Co...

Page 3: ...of a control If you have questions call the Honeywell Customer Response Center at 1 800 468 1502 5 FEET 1 5 METERS YES NO NO NO M11338 Location Install the thermostat about 5 ft 1 5m above the floor in an area with good air circulation at average room temperature See Fig 2 Do not install the thermostat where it can be affected by drafts or dead spots behind doors and in corners hot or cold air fro...

Page 4: ...tat restrict all wiring to the shaded area in the center of the terminals See Fig 5 KEEP WIRING IN SHADED AREA MOUNTING SCREW HOLE MOUNTING SCREW HOLE WIRING ENTRANCE HOLE M11331 G C R Y W1 L W2 E B O Fig 5 Restrict wiring to shaded area The T8011R Heat Pump Thermostat is powered directly from the system transformer Refer to Fig 6 for typical wiring hookup Mounting Thermostat to Wallplate 1 Slide ...

Page 5: ... CONTACTOR COMPRESSOR CONTACTOR HEAT FAN RELAY RELAY EMERGENCY HEAT RELAY G C THERMOSTAT LOGIC THERMISTOR SENSOR POWER SUPPLY ON AUTO STAGE 2 RELAY STAGE 1 RELAY FAN SWITCH M11333 Fig 6 T8011R two stage heat one stage cool wiring diagram with manual changeover Fig 7 Mounting thermostat to wall plate DASHED LINES INDICATE TABS ON BACK OF THERMOSTAT ENGAGE TABS AT TOP OF THERMOSTAT WITH SLOTS ON MOU...

Page 6: ...the key momentarily displays 2 When the keys are released these one digit codes are no longer displayed 2 Setting C or F a Press the key again to display the current setting b Press the key to change the C or F indication 3 Setting Heat Cycle Rate see Table 1 for cycle rate options NOTE Cycle rate settings are for second stage heat First stage heat and cool are fixed at 3 cph a Press the key to di...

Page 7: ...d weekends Four time periods are available during weekdays and weekends WAKE LEAVE RETURN and SLEEP IMPORTANT Always press the keys with your fingertip or similar blunt tool Sharp instruments like pens and pencil points can damage the keyboard Setting the Current Time and Day 1 To Set Current Time Press Select twice Press or to set current time While setting the current time the word SET is displa...

Page 8: ...ress and hold the Hold and Select keys simultaneously The display will begin counting down from 36 to zero b The thermostat display will go blank then will display the current time and temperature c Release keys the program has reverted to the preprogrammed time and temperature settings Setting Temperature Hold Slide the SYSTEM switch to the heat or cool position Temporary Temperature Hold 1 Press...

Page 9: ... power or a change in the SYSTEM switch setting can cause the outputs to turn off Table 3 shows the sequence of operations for the Fan and System settings Em Ht With the system switch at Em Ht the thermostat controls the emergency heat On a call for emergency heat the E G and L terminals are energized and an indicator points to Em Ht on the display L terminal is powered continuously while system s...

Page 10: ...ACE THERMOSTAT PARTIAL DISPLAY OR IS FLASHING AND COOLING OR FIRST STAGE HEATING WILL NOT OPERATE INOPERATIVE THERMOSTAT SEE THE INSTALLER SETUP SECTION FOR INSTRUCTIONS STILL IN INSTALLER SETUP MODE RECONFIGURE THE DISPLAY SEE INSTALLER SETUP SECTION TEMPERATURE DISPLAY IS INCORRECT THERMOSTAT IS CONFIGURED FOR F OR C DISPLAY CHECK THAT C TERMINAL IS CONNECTED TO THE SYSTEM TRANSFORMER COMMON CHE...

Page 11: ...T8011R PROGRAMMABLE HEAT PUMP THERMOSTAT 68 0196 1 11 ...

Page 12: ... Kong Home and Building Control Honeywell Limited Honeywell Limitée 35 Dynamic Drive Scarborough Ontario M1V 4Z9 Honeywell Latin American Region 480 Sawgrass Corporate Parkway Suite 200 Sunrise FL 33325 68 0196 1 G H Rev 9 00 Home and Building Control Honeywell 1985 Douglas Drive North Golden Valley MN 55422 Printed in U S A on recycled paper containing at least 10 post consumer paper fibers www h...

Reviews: