Q7100A,C,D THERMOSTAT SUBBASES

Fig. 2. Two T7047G Sensors providing a

temperature averaging network for a

T7100/Q7100 Thermostat/Subbase.

Fig. 3. Two T7047C Sensors and one T7047G Sensor

providing a temperature averaging network

for a T7100/Q7100 Thermostat/Subbase.

Fig. 5. Five T7047G Sensors providing a

temperature averaging network for a

T7100/Q7100 Thermostat/Subbase.

M4838

T

T

SUBBASE

T

T

T7047G

T7047G

T

T

M4839

T

T

SUBBASE

T

T

T7047C

T

T

T7047C

T

T

T7047G

M4840

T

T

T

T

SUBBASE

T7047C

T

T

T7047C

T

T

T7047C

T

T

T7047C

Fig. 4. Four T7047C Sensors providing a

temperature averaging network for a

T7100/Q7100 Thermostat  Subbase.

M4841

T

T

SUBBASE

T

T

T7047G

T

T

T7047G

T

T

T7047G

T

T

T7047G

T

T

T7047G

Fig. 1. Typical location of thermostat or remote-mounted sensor.

5 FEET

[1.5 METERS]

YES

NO

NO

NO

M10074

Summary of Contents for TRADELINE Q7100A

Page 1: ...ions and on the product to make sure the product is suitable for your application 3 Installer must be a trained experienced service technician 4 After completing installation use these instructions to check out the product operation CAUTION Disconnect power supply to prevent electrical shock or equipment damage Location Subbase without Remote Mounted Temperature Sensor Install the subbase about 5 ...

Page 2: ...iding a temperature averaging network for a T7100 Q7100 Thermostat Subbase M4838 T T SUBBASE T T T7047G T7047G T T M4839 T T SUBBASE T T T7047C T T T7047C T T T7047G M4840 T T T T SUBBASE T7047C T T T7047C T T T7047C T T T7047C Fig 4 Four T7047C Sensors providing a temperature averaging network for a T7100 Q7100 Thermostat Subbase M4841 T T SUBBASE T T T7047G T T T7047G T T T7047G T T T7047G T T T...

Page 3: ... to Fig 9 through 15 for typical hookups A letter code is located near each terminal for identification CAUTION Disconnect power before wiring to prevent electrical shock or equipment damage 1 Loosen the terminal screws on the back of the thermostat and connect the system wires See Fig 8 IMPORTANT Use 18 gauge color coded thermostat cable for proper wiring 2 Securely tighten each terminal screw 3 ...

Page 4: ...ELAY 1 Y2 RH T D REMOTE TEMPERATURE SENSOR HEAT RELAY 2 W1 B T COMPRESSOR CONTACTOR 2 HEAT DAMPER L1 HOT L2 2 COMPRESSOR CONTACTOR 1 3 2 3 REMOTE SETBACK TIMER L1 HOT L2 M11089 COMPRESSOR CONTACTOR FAN RELAY O G Y1 COOL CHANGEOVER VALVE HEAT CHANGEOVER VALVE SUBBASE X HEAT RELAY AUX HEAT RELAY EM HT RELAY W1 R T T D D SENSOR TIMER EQUIPMENT MONITOR X1 E B W2 L1 HOT L2 POWER SUPPLY PROVIDE DISCONNE...

Page 5: ... temperature sensor and remote setback timer L1 HOT L2 M4834B FAN RELAY D O E W3 Y2 COOL CHANGEOVER VALVE SUBBASE 2 X B G EM HT RELAY R T D REMOTE TEMPERATURE SENSOR AUX HT RELAY Y1 T COMPRESSOR CONTACTOR 2 CAUTION EQUIPMENT DAMAGE WILL OCCUR IF POWER IS CONNECTED TO THE D TERMINALS POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED SELECT MODELS HAVE LEDS X4 NEEDS TO BE JUM...

Page 6: ...Home and Building Control Honeywell Limited Honeywell Limitée 155 Gordon Baker Road North York Ontario M2H 2C9 69 0931 3 Rev 2 98 L C Home and Building Control Honeywell Inc Honeywell Plaza P O Box 524 Minneapolis MN 55408 0524 www honeywell com ...

Reviews: