Summary of Contents for TRADELINE Q314

Page 1: ...equipment damage 2 To avoid dangerous accumulation of fuel gas turn off gas supply at appliance service valve before starting installation and perform Gas Leak Test after completion of installation 3 Do not bend pilot tubing at the control or pilot after compression nut has been tightened Gas leakage at the connection may result Follow appliance manufacturer s instructions if avail able otherwise ...

Page 2: ...UST MISSES MAIN BURNER M3285 PILOT BURNER BODY TIGHTEN NUT ONE TURN BEYOND FINGER TIGHT FITTING BREAKS OFF AND CLINCHES TUBING AS NUT IS TIGHTENED TO GAS CONTROL M3295 INSTALL THERMOCOUPLE OR THERMOPILE PUSH IN DESIGN 1 Insert thermocouple or thermopile tip into hole or barrel provided beneath pilot burner See Fig 4 2 Push in firmly until thermocouple or thermopile is locked into place ATTACHMENT ...

Page 3: ...all burrs 5 Insertnewcompressionnutoverpilottubingandslide out of the way 6 Insert new orifice into pilot burner and tighten se curely 7 Push pilot tubing into orifice until it bottoms 8 Whileholdingtubingallthewayin slidecompression fitting into place and engage threads Turn until finger tight 9 Using a wrench tighten compression fitting one turn beyond finger tight Startup and Checkout PERFORM G...

Page 4: ...e pilot flame is properly adjusted 2 Ensure power unit connections clean and tight 3 If power unit still fails to hold in use the W129A Millivoltmeter to obtain the open and closed circuit voltage generated by the thermocouple or generator 4 Compare measured open and closed circuit voltage values to Acceptable Range Charts in W129A Manual 5 If W129A Millivoltmeter or other meter is not avail able ...

Page 5: ...burner flame See Adjust Pilot Flame section EFFECTIVE IGNITION TEST 750 mV SYSTEMS The Effective Ignition Test assures that the pilot flame ignitesthemainburnerwithinfoursecondsfromthetimegas reaches the main burner In this test the pilot flame is just sufficient to open the main gas valve 1 Light the main burner according to the appliance manufacturer s instructions and allow to burn at least fiv...

Page 6: ...6 ...

Page 7: ...7 69 0519 3 ...

Page 8: ...e and Building Control Helping You Control Your World Honeywell Inc Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley MN 55422 Scarborough Ontario M1P 2V9 Printed in U S A QUALITY IS KEY ...