VISIONPRO
®
8000 WITH REDLINK™
47
68-0312—01
711
Air Filter 1
Reminder
Note: “1” is not
displayed if there
is only 1 filter.
Off
Run Time:
10, 20, 30, 45, 60, 90, 120, 150
days
Calendar:
30, 45, 60, 75 days
3, 4, 5, 6, 9, 12, 15 months
Off
Both
No
711
Air Filter 2
Reminder
Off
Run Time:
10, 20, 30, 45, 60, 90, 120, 150
days
Calendar:
30, 45, 60, 75 days
3, 4, 5, 6, 9, 12, 15 months
Off
Both
No
712
EAC Cell
Reminder
Off
Calendar Months:
6, 7, 8, 9, 10, 11, 12 months
Off
Both
No
Electronic Air Cleaner Cell Cleaning Reminder
712
EAC Pre-Filter
Reminder
Off
Calendar Months:
3, 4, 5, 6 months
Off
Both
No
Electronic Air Cleaner Pre-Filter Cleaning
Reminder
712
EAC Post Filter
Reminder
Off
Calendar Months:
6, 7, 8, 9, 10, 11, 12 months
Off
Both
No
Electronic Air Cleaner Post-Filter Replacement
Reminder
800
Humidifier Type
None
Steam
Bypass / Fan Pwrd
None
Both
No
801
Sensor for Hum
T-Stat Sensor
Remote Indoor Sensor Name
Remote Indoor Sensor Name
Remote Indoor Sensor Name
Remote Indoor Sensor Name
Remote Indoor Sensor Name
Remote Indoor Sensor Name
(Up to 6 Remote Indoor Sensors)
T-Stat Sensor Both
No
Select a sensor to control humidification
(thermostat or an optional remote sensor). If
multiple sensors are installed, you can use a
different sensor for dehumidification control.
See “Humidification control” beginning on
page 111.
Note: Humidity sensing cannot be averaged.
803
Humidifier Wiring
None
U1
U2
U3
Thermostat
defaults to the
next unused
universal
terminal (U1,
U2, U3).
Both
No
Number of Universal Outputs:
TH8321 Thermostat: U1 terminals
Equipment Interface Module (EIM): U1, U2
and U3 terminals
U1, U2, U3 are dry contacts that require
power. See “Wiring IAQ Equipment or a Heat/
Cool Stage to the Universal Terminals”
beginning on page 128.
Table 2. Installer Setup (ISU) Table. (Continued)
ISU
Number
Installer Setup
Name
Settings
Default
Residential,
Commercial
or Both
Requires
EIM
Notes