Doc No: MI5008E – Revision 7 – ENG
Data Processing Racks
TA3840 Installation Manual
12
TA3840S - Safety unit
For best installation performance, the procedure below must be carried out step by step.
●
Check the On/Off switch on the front panel is in "Off" position.
If the rack is delivered in a cabinet by Honeywell Marine, connecting points 1 and 2 are
pre-wired.
Connect the mains supply cable to the terminal block (neutral and phase wires) using wires max. 3
x 2.5 mm².
Connect the ground wire to the terminal screw provided for this purpose.
Check the voltage marked next to the terminal is the same as that of the
mains system.
Plug in and secure the DB9 cable of interconnection between racks (transmitter BUS to TA3840C
rack).
Eventually, plug in and secure the DB9 cable from another TA3840S rack.
Connect the cable of each radar transmitter to the 1 to 16 connectors, respecting the wires
identification, the +/- polarity for supply and ground connection.
Note: in order to respect the channel identification, refer to the
I
/0 list of the manufacturer
file.
1
2
3
2
1
3
4
5