Honeywell T812 Installation Instructions Manual Download Page 2

T812, TS812 THERMOSTATS

69-1606ESF-3

2

Fig. 1. Internal view of T812 with adjustable heat 

anticipator.

Wiring and Mounting

All wiring must comply with local codes and ordinances.

Fig. 2. Mounting hole locations for models without 

subbase.

T812 and TS812 Models Without Subbase

1.

In replacement applications, inspect the old wires 
for frayed or cracked insulation and replace any 
wires in poor condition; in new installations, run two 
wires to the location.

2.

Grasping the thermostat cover on the top and the 
bottom with one hand, push in on the bottom cen-
ter and pull outward until the cover snaps free from 
the thermostat base.

3.

Connect the thermostat wires to the appropriate 
terminals on the thermostat back. See Fig. 4-8 for 
typical hookup diagrams. 

4.

Push any excess wire back through the hole and 
plug any opening to prevent drafts that could affect 
thermostat performance.

5.

Adjust the heat anticipator (select models) to 
match the current draw of the system primary con-
trol. See Heat Anticipator Setting section.

6.

Fasten the thermostat to the wall with screws 
through the mounting holes on the upper left and 
right sides of the device. See Fig. 2. 

7.

Replace the thermostat cover.

Fig. 3. Mounting hole locations for models with 

subbase.

T812 Models With Subbase

1.

In replacement applications, inspect the old wires 
for frayed or cracked insulation and replace any 
wires in poor condition; in new installations, run the 
appropriate number of wires to the location.

2.

Grasping thermostat cover on top and bottom with 
one hand, push in on bottom center and pull out-
ward until cover snaps free from thermostat base.

3.

Disconnect thermostat from subbase by unscrew-
ing the three screws under the thermostat cover. 
See Fig. 1.

4.

Connect the wires to the terminals on the front of 
the subbase. See Fig. 4-8.

5.

Push any excess wire back through the hole and 
plug any opening to prevent drafts that could affect 
thermostat performance.

6.

Loosely fasten thermostat subbase to the wall with 
a screw through the right mounting hole. Adjust the 
subbase so it is approximately level and start the 
second screw through the left mounting slot. 

7.

Level the thermostat subbase for appearance only; 
it is not required for accurate operation.

8.

Tighten the mounting screws. See Fig. 3.

9.

Mount the thermostat to the thermostat subbase by 
tightening the three screws. See Fig. 1.

10.

Adjust the heat anticipator (select models) to 
match the current draw of the system primary con-
trol. See Heat Anticipator Setting section.

11.

Replace the thermostat cover.

M20496A

MOUNTING HOLE 
(THERMOSTAT 
TO WALL)

MOUNTING
TABS (3)

MOUNTING HOLE 
(THERMOSTAT TO WALL)

TEMPERATURE
SETTING LEVER

SNAP SWITCH CONTACTS

ADJUSTABLE HEAT

ANTICIPATOR 

SCALE

ADJUSTABLE

HEAT ANTICIPATOR

INDICATOR LEVER

SCREWS (3) 

USED

TO MOUNT

THERMOSTAT

ONTO

SUBBASE

BIMETAL
ELEMENT

M20883

MOUNTING HOLES (2) USED TO 
MOUNT THERMOSTAT TO WALL 
(FOR MODELS WITHOUT SUBBASE).

M20889

MOUNTING HOLES (2) USED TO 
MOUNT THERMOSTAT TO WALL 
(FOR MODELS WITH SUBBASE).

Summary of Contents for T812

Page 1: ...s suitable for your application 3 Installer must be a trained experienced service technician 4 After installation is complete check out product operation as provided in these Instructions CAUTION Electrical Shock Hazard Can cause personal injury or equipment damage Disconnect power supply before beginning installation Location Locate the thermostat about 5 ft 1 5m above the floor in an area with g...

Page 2: ...ion in new installations run the appropriate number of wires to the location 2 Grasping thermostat cover on top and bottom with one hand push in on bottom center and pull out ward until cover snaps free from thermostat base 3 Disconnect thermostat from subbase by unscrew ing the three screws under the thermostat cover See Fig 1 4 Connect the wires to the terminals on the front of the subbase See F...

Page 3: ... T812A THERMOSTAT GAS VALVE COMBINATION FAN AND LIMIT CONTROL FAN MOTOR TRANSFORMER M20438A TH1 TH2 PP PP LIMIT CONTROL PILOT CONTROL IF USED MILLIVOLT GENERATOR R W TS812 THERMOSTAT 1 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED M20439 TO 12 Vdc POWER SUPPLY GAS VALVE W R T812B THERMOSTAT HEAT L2 L1 1 M20440 FAN COOL 1 POWER SUPPLY PROVIDE DISCONNECT MEANS AND OVERL...

Page 4: ...wire the thermostat into the system but do not attach it to the wall If the thermostat is already mounted remove it from the wall leaving it connected to the system wiring Connect an ammeter of the appropriate range about 0 0A to 2 0A between the terminals on the back of the thermostat Move the temperature setting lever to a low setting so the contacts are broken In cold weather it may be necessar...

Page 5: ... 3 El instalador debe ser un técnico de servicio capacitado y experimentado 4 Después de terminar la instalación verifique el funcionamiento del producto como se indica en estas instrucciones PRECAUCIÓN Riesgo de descarga eléctrica Puede ser causa de lesiones a la persona o daño al equipo Antes de iniciar la instalación desconecte el suministro de energía Ubicación Coloque el termostato aproximada...

Page 6: ... extienda dos cables hacia la ubicación 2 Sujetando la cubierta del termostato por la parte superior e inferior con una mano empuje hacia adentro el centro de la parte inferior y estire hacia afuera hasta que la cubierta se desprenda de la base del termostato 3 Desconecte el termostato de la base inferior desatorni llando los tres tornillos que se encuentran bajo la cubierta del termostato Consult...

Page 7: ...DE VENTILADOR Y CONTROL DE LÍMITE MOTOR DEL VENTILADOR TRANSFORMADOR MS20438A TM1 TM2 PP PP CONTROL DE LÍMITE CONTROL DE PILOTO SI SE USA GENERADOR DE MILIVOLTIOS R B TERMOSTATO TS812 1 1 SUMINISTRO DE ENERGÍA PROPORCIONE UN MEDIO DE DESCONEXIÓN Y DE PROTECCIÓN CONTRA UNA SOBRECARGA SEGÚN SE REQUIERA MS20439 A SUMINISTRO DE ENERGÍA DE 12 V CD VÁLVULA DE GAS B R TERMOSTATO T812B CALOR L2 L1 1 MS204...

Page 8: ...a pared Si el termostato ya está instalado quítelo de la pared dejándolo conectado al cableado del sistema Conecte un amperímetro del rango apropiado aproximada mente de 0 0 A a 2 0 A entre las terminales que se encuentran en la parte posterior del termostato Mueva la palanca de ajuste de temperatura a un valor más bajo de tal manera que los contactos se interrumpan En clima frío tal vez sea neces...

Page 9: ... une formation pertinente 4 Une fois l installation terminée vérifier le fonction nement du produit en suivant les présentes instruc tions MISE EN GARDE Risque de choc électrique Peut causer des blessures ou des dommages matériels Couper l alimentation avant d installer ce produit Choix de l emplacement Installer le thermostat à environ 1 5 m 5 pi au dessus du plancher dans un endroit où la circul...

Page 10: ...n thermostat s assurer que l isolant des anciens fils n est ni craquelé ni effiloché remplacer tous les fils abîmés Dans le cas d une nouvelle installation amener les fils appropriés jusqu à l emplacement choisi 2 Saisir d une main la partie supérieure et la partie inférieure du couvercle du thermostat appuyer sur la partie inférieure au centre et tirer pour dégager le couvercle de la base du ther...

Page 11: ...ON FOURNIR AU BESOIN UN DISPOSITIF DE COUPURE ET UNE PROTECTION CONTRE LES SURCHARGES MF20437 LIMITEUR THERMOSTAT T812A VANNE À GAZ RÉGULATEUR DE VENTILATEUR ET LIMITEUR COMBINÉS MOTEUR DU VENTILATEUR TRANSFORMATEUR VENTILATEUR MF20438A TH1 TH2 PP PP LIMITEUR RÉGULATEUR DE VEILLEUSE LE CAS ÉCHÉANT GÉNÉRATEUR À TENSION MV R W THERMOSTAT TS812 1 1 ALIMENTATION FOURNIR AU BESOIN UN DISPOSITIF DE COUP...

Page 12: ...s nominales du courant ne sont pas indiqués raccorder le thermostat au système sans toutefois le fixer au mur Si le thermostat est déjà fixé au mur le retirer mais le laisser brancher au système Raccorder un ampèremètre d échelle appropriée 0 0A à 2 0 A environ aux bornes à l arrière du thermostat Déplacer le levier de réglage à une température plus basse pour faire ouvrir le circuit Lorsque la te...

Reviews: