Honeywell Symphony Frequently Asked Questions Manual Download Page 6

 

 

 

- 6 -

 

 

 

Step-by-Step 

Tech Support 

 Updated 1/13/09 

This section will explain how to troubleshoot the Internet connection to your Symphony.

 

 

Before starting, review the Networking 101 presentation on the CD included with the Symphony. A basic 
understanding of networks is essential to this procedure. Next identify the problem. Run the Network Diagnostics in 
the Symphony. Which of the following applies:  

 

 

My Physical Link failed.  

 

My Physical Link is OK, but I failed to get an IP address.  

 

My Physical Link is OK, and I have an IP address, but I can’t reach the AUI servers.  

 

I can reach the AUI servers, but I don’t have a web link on the Symphony screen. 

My Physical Link failed.

 

1.

 

This literally means that you have a wiring problem between the Symphony and the device it is connected 
to.  

2.

 

Check your connectors.  

3.

 

Make sure that there is not a kink in the wire.  

4.

 

Try connecting the Symphony directly to the router using a short pre-manufactured Ethernet cable (patch 
cord). Use a cable that you can verify the integrity of by using it on another device such as a computer.  

5.

 

Make sure that you are on the proper port of the router. For example, a port marked “uplink”, is used for 
programming only – not for connecting to network devices.  

 My Physical Link is OK, but I failed to get an IP address. 

 

1.

 

This could still be a problem with the cable even though it passed the test above.  

2.

 

The Symphony gets its IP address from the DHCP service on the router when it is powered up or the 
network is restarted. Try resetting the power on the symphony or restarting the network. You should restart 
the Symphony after each of these steps.  

3.

 

Try connecting the Symphony directly to the router using a short pre-manufactured Ethernet cable (patch 
cord). Use a cable that you can verify the integrity of by using it on another device such as a computer.  

4.

 

Verify that a computer on the network is able to get its address through DHCP.  

5.

 

Try connecting the Symphony to the same port of the router that you know a computer is able to get its 
address through.  

6.

 

Make sure that you are on the proper port of the router. For example, a port marked “uplink”, is used for 
programming only – not for connecting to network devices. 

My Physical Link is OK, and I have an IP address, but I can’t reach the AUI servers.

  

1.

 

Verify that the computer network address and the Symphony network address are on the same network 
when compared to the subnet mask.  

2.

 

If they are on different networks, DHCP is not functioning properly. Remember, the IP address must match 
for each of the 4 address digits in which the subnet mask is 255.  

3.

 

Go to Services setup from the network setup screen and make sure that RCPP, Blowfish, and port 80 are 
selected.  

4.

 

Go to Redir setup from the network setup screen and make sure that the address is selected as Normal.  

5.

 

Your router may be implementing a firewall that blocks the network communication of the symphony. 
Your router must allow messages using HTTP protocol on PORT 80 Contact the vendor of the router for 
assistance in verifying this.  

I can reach the AUI servers, but I don’t have a web link on the Symphony screen. 

 

 

You need to enable the Symphony Console in a Customer account through the Alarmnet web server. You 
next need to add the console to the customer account and select the content for the user’s home page.  

 

Return to the table of contents

 
 

Summary of Contents for Symphony

Page 1: ... The Symphony keypad is compatible with the following Ademco panels Vista 20P Rev 3 and the 20PS Support s 2 Symphony keypads Vista 20p Rev 5 and higher will support up to 4 Symphony keypads Vista 20PI Support s 4 Symphony keypads First Alert FA148CP Supports 2 Symphony Keypads First Alert FA168CPS Supports 2 Symphony Keypads Vista 128BP 250BP Supports 3 Symphony Keypads Vista 128BP 250BP Rev 4 Su...

Page 2: ...ote Only 1 Symphony keypad can be set above address 2 In the control panel device programming Program a device address for the Symphony keypad as an Alpha Keypad Set for the partition that you want and for the AUI prompt enter 1 for YES Set the Address in a Vista 20P Rev 3 20PS 20PI and FA148CP 168CPS control panel These panels support up to TWO Symphony keypads The 20PI supports 4 The Symphony de...

Page 3: ...ht operation of keypad You can use alternate power source or same power source used on pin 2 Only wiring pin 2 will result in dim back light and reduced life of the back light so pin 1 must be powered under normal conditions Category 5 Ethernet connection to the network router This connection is required for a network connection for Internet features Category 5 4 twisted pair 24AWG Connects from R...

Page 4: ... If the AUI and GMT time differ by 10 seconds or more the AUI time will be reset The Symphony will also send time to the control panel every hour This 1 hour timer starts on power up or when Sync to Network is selected if it was not set at power up This is true for all panels that support the AUI 20P series 128 250BP series 128 250FBP series and FA1660C 1700C as well Without Network Connection The...

Page 5: ...k your setup 3 Wait for the system to update Verify that your Email is compatible 1 Your email service provider must use POP3 Post Office Protocol format with no security encryption 2 Some ISPs such as AOL use proprietary mail protocols that are not compatible with the Symphony 3 MSN uses encryption that causes it to be incompatible 4 Yahoo has POP3 email available but you must specifically sign u...

Page 6: ...start the Symphony after each of these steps 3 Try connecting the Symphony directly to the router using a short pre manufactured Ethernet cable patch cord Use a cable that you can verify the integrity of by using it on another device such as a computer 4 Verify that a computer on the network is able to get its address through DHCP 5 Try connecting the Symphony to the same port of the router that y...

Page 7: ...orm then click on CREATE ACCOUNT at the bottom 3 The primary username and password is for the end user to log in to the end user site to edit the web content for the Symphony This information will be emailed to the customer along with a link to the end user home page http symphony alarmnet com Add the Symphony console to the account 1 Click on MANAGE ACCOUNTS 2 Then for the account you are working...

Page 8: ...he Symphony in the control panel based on its device address For Vista 128BP 250BP FA1660C and 128FBP panels support up to THREE Symphony keypads For Vista 250FBP and FA1700C panels support only ONE Symphony Keypad 1 The Symphony defaults for device address 01 If you have multiple Symphony keypads you must make each one a separate address 2 In the control panel device programming Program a device ...

Reviews: